Specifications
AC Current Capacity |
|
Input: | 15 Amp capacity required (10 Amp for the |
Output: | 15 Amp RMS (both outlets combined) (10 Amp for the |
| |
AC Noise Attenuation |
|
Transverse (Differential) Mode | >40dB from 10kHz to 100kHz |
| >80dB from 100kHz to 1GHz |
| (linear attenuation curve from 0.05 to 100Ω line impedance) |
Transient Voltage Surge | 120VAC (230VAC for |
Suppression | Series |
Domestic: | with Zero Ground contamination |
188V peak clamping @ 6000V/3000A input | |
International: | 276V peak clamping for |
Extreme Voltage Shutdown | 137 VAC typically |
| (270 VAC typically for the |
| (260 VAC typically for the |
Dimensions & Weight | 1.75” (H) x 5” (W) x 8.5” (D), 3 lbs. |
Safety Agency Listing | CE / TUV / |
| Furman Sound, Inc. |
| 1997 South McDowell Blvd. |
| Petaluma, California |
| Phone: |
| Fax: |
| Web: www.furmansound.com |