SPECIFICATIONS
Current rating: 16 amps
Operating Voltage:
180 to 280 VAC (UK version, 260 VAC)
Over Voltage Shutdown:
280 VAC typically (UK version, 260 VAC)
Voltmeter Accuracy:
PL-PRO DE II / PDE II & PM-PRO E II / PE II: ±1.5 VAC
Current Meter Accuracy:
Spike Protection Modes:
Line to neutral, zero ground leakage
Spike Clamping Voltage:
376 Vpk (266 VAC RMS)
Response time:
1 nanosecond
Maximum surge current: 6,500 amps
Noise attenuation: 10 dB @ 10 kHz 40 dB @ 100 kHz 100 dB @ 10 MHz
Linear attenuation curve from 0.05 - 100 ohms line impedance
Mechanical:
Dimensions: 1.75” H x 19” W x 10.5” D.
Weight: 11 lbs (5 kg).
Construction: Steel chassis, .125” brushed and black anod- ized aluminum front panel; glass epoxy printed circuit boards
Power Consumption: 12 watts
Safety Agency Listings:
CE
Make sure to pick up one of Furman’s goose- neck lights – the perfect accessory for your Series II Power Conditioner.
GN-LED
GN-I
Furman Sound, Inc.
1997 South McDowell Blvd.
Petaluma, California
Phone: +1
Web: www.furmansound.com