SPECIFICATIONS OF DSC-6/6A

GENERAL CHARACTERISTICS

1.Rules and Regulations CCIR Rec. 493 (Class A), 541

IMO Res. A609 (15), CEPT TR/34-01

2.Distress Call and Message

Distress Call and Message (RR3112: Format specifier (distress), Self-ID, Nature of distress, Distress coordinates, Time, Telecommand, EOS, ECC)

3.Class of Emission

DSC: F1B/J2B (J2B w/FS-1562)

Voice:J3E, H3E (2182 kHz)

TTY:

F1B/J2B (J2B w/FS-1562)

4.Manual Setting or Scan of Distress Frequencies MF/HF DSC:

2187.5, 4207.5, 6312, 8414.5, 12577, 16804.5 kHz Corresponding MF/HF NBDP (not scanned): 2174.5, 4177.5, 6268, 8376.5, 12520, 16695 kHz TP: 2182, 4125, 6215, 8291, 12290, 16420 kHz

5.Message Storage Receive:

50 distress messages max. plus 50 non-distress messages Transmit:

50 non-distress messages plus 99 files containing station ID, telephone no., frequency, etc.

6.Nav Data IEC61162

7.Alarms

Aural and visual on receipt of distress, urgency or general calls

8.Display

24 characters x 2 lines

Character composition: 5 x 7 dots LCD with adjustable backlighting

9. Modulator and Demodulator

Level: -30 dBm to +10 dBm at 600 ohms, balanced

Frequency: Mark 1615 Hz, Space 1785 Hz, 100 baud

Stability: ±0.5 Hz

RECEIVER CHARACTERISTICS OF DSC-6A

Receive Frequency: 2187.5 kHz

Sensitivity: Error rate 1 % at 0 dBµV

POWER SUPPLY

10.8 - 40.0 VDC, 15 W

115/230 VAC thru AC/DC changeover supply

EQUIPMENT LIST

Standard

1.DSC terminal

2.Installation materials and spare parts

Optional

1.Mounting bracket

2.Printer PP-500

Weight: 3.5 kg

 

 

 

 

 

 

 

299

11.8"

 

 

254.1

10.0"

 

258

10.2"

 

127

5.0"

 

 

 

 

 

 

5.6"

 

 

 

 

 

 

 

143

 

 

3.5"

 

 

 

 

 

 

 

 

 

 

 

6 -˘7.5

 

 

89

(95

3.7")

(95

3.7")

 

(89

3.5")

 

 

DSC signal,

DSC ship business and routine

DSC distress

For DSC-6A

telephony,

(scanning watch)

and safety

 

telex

 

(continuous watch)

 

 

FS-1562

 

DSC-6/6A

 

 

MF/HF DSC

 

 

 

RECEIVER

 

 

 

AA-50

 

 

Setting telecommand,

 

working freq., etc.

 

NBDP Terminal

 

 

DP-5/6

 

 

 

DSC signal,

DSC ship business and routine

 

telephony,

For DSC-6A

telex

(scanning watch)

DSC distress

 

 

 

ALLWAVE RECEIVER

and safety

 

RV-107

(continuous watch)

FS-1562

 

MF/HF DSC

RECEIVER

AA-50

DSC-6/6A

Setting telecommand, working freq., etc.

NBDP Terminal

DP-5/6

Centralized control/monitoring

NAV

dataPosition

C-SB-SPEVV-CO max.m30P,2x0.2

alarmsDistress

SB-SPEVV-CO-C, m302P,x0.2max MF/HFforports(2 VHFandDSCDSC)

Distress

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

message

 

 

 

 

 

 

 

controller

 

 

 

 

 

 

 

DMC-5

 

 

 

 

 

 

 

 

NAVTEXReceiver NX-500

Watch2182receiver AA-45B

ReceiverEGC EGC-5

Alarms

 

 

 

 

 

 

Captain’s room

DSC-6/6A standard system

PRINTER

 

 

 

 

Operator’s room

 

 

1.25-DPYC

 

 

 

 

PP-500/510

Option

57FE-338-205W, 5 m

 

 

1.25-VCTF m32C,x

1.25-DPYC

 

 

 

 

 

 

 

 

 

24 VDC

 

 

115 or 230 VAC

24 VDC

 

 

 

 

 

(For PP-500)

(For PP-510)

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

FURUNO U.S.A., INC.

FURUNO DANMARK AS

99043N Printed in Japan

Camas, Washington, U.S.A.

Hvidovre, Denmark

 

 

 

Phone: +1 360-834-9300 Telefax: +1 360-834-9400

Phone: +45 36 77 45 00

Telefax: +45 36 77 45 01

 

FURUNO (UK) LIMITED

FURUNO NORGE A/S

 

Denmead, Hampshire, U.K.

Ålesund, Norway

 

 

Phone: +44 1705-230303 Telefax: +44 1705-230101

Phone: +47 70 102950

Telefax: +47 70 127021

 

FURUNO FRANCE S.A.

FURUNO SVERIGE AB

 

Bordeaux-Mérignac, France

Västra Frölunda, Sweden

 

Phone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01

Phone: +46 31-7098940

Telefax: +46 31-497093

 

FURUNO ESPANA S.A.

FURUNO SUOMI OY

 

Madrid, Spain

Helsinki, Finland

Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97

Phone: +358 9 3417570 Telefax: +358 9 3415716

Page 2
Image 2
Furuno DSC-6/6A Rules and Regulations Ccir Rec Class a, Distress Call and Message, Class of Emission, Display, Standard