SPECIFICATIONS OF FCV-291/FCV-292

1.Display

10" color CRT, 232 x 240 pixels, 16-colors

2.Display Modes Single for FCV-291

Single LF or HF or Dual for FCV-292

Common features to FCV-291/292: Marker Zoom, Bottom-Lock, Bottom Discrimination, Bottom Zoom, A-scope (HF in dual mode for FCV-292) and NAV data

3.Frequency

FCV-291: Single frequency to choose from 28, 38*, 50, 88 or 200 kHz

FCV-292: Dual frequencies to choose from 28, 50, 88 or 200 kHz

*38 kHz transducer must be arranged locally.

Output: Water depth

$SDDBT, $SDDPT

Water temperature*

$YCMTW

Speed*

$VWVHW

8.Output Power (Specify when ordering) 1, 2 or 3 kW rms

POWER SUPPLY (Specify when ordering)

10.5- 20.0 VDC or 18 - 40.0 VDC, less than 45 W 115/230 VAC with optional rectifier PR-62

POWER CONSUMPTION

45 W (1 kW), 48 W (2 kW), 50 W (3 kW) ENVIRONMENT (IEC test method)

Temperature:

-15° C to +55° C (IEC 945)

Water resistance:

IPX2 (IEC 529)

 

(protected against dripping water)

4.

Range Settings

 

 

 

 

 

 

 

 

 

EQUIPMENT LIST

 

 

 

 

 

 

 

 

 

Basic Range (Factory setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

 

 

 

 

 

m

5,

10,

20,

40,

80,

150,

300,

 

500

 

 

 

 

 

 

 

 

 

 

 

1.

Display Unit CV-291/CV-292

 

 

 

 

 

 

1 unit

 

ft

15,

30,

60,

120,

200,

400, 1000,

1500

 

 

 

 

 

 

 

 

(Specify output power and power supply when ordering)

 

fa

3,

5,

10,

20,

40,

80,

150,

 

250

 

 

 

2. Installation materials and standard spare parts

 

1 set

 

p/b

3,

5,

10,

20,

40,

80,

150,

 

250

 

 

 

Optional

 

 

 

 

 

 

 

 

 

 

(Range scales can be selected from 5 to 4,000 m

 

 

 

 

 

 

 

 

 

 

 

 

1. Speed & temperature sensor ST-01MSB (Thru-hull, bronze)

 

in Menu)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Temperature sensor T-02MSB (Thru-hull, bronze)

 

 

Zoom Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

EMI filter FP02-03900

 

 

 

 

 

 

 

 

 

x2, x3, x4 or x5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

NMEA cable MJ-A6SPF0012-050 (5 m)

 

 

 

 

 

 

Phased Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Rectifier PR-62 for 115/230 VAC mains

 

 

 

 

 

 

Up to 4,000 m (9,000 ft, 2,000 fa, 2,000 p/b) in 1 to 100 m

 

 

 

 

 

 

TRANSDUCERS

 

 

 

 

 

 

 

 

 

(ft, fa, p/b) steps depending on selected range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specify operating frequencies when ordering. Select one

5. Pulselength and Pulse Repetition Rates

 

 

 

 

 

 

 

 

for FCV-291, two for FCV-292.

 

 

 

 

 

 

 

 

Range (m)

5,

10,

20,

40,

80,

150,

300, 500

 

 

 

 

 

 

 

 

 

 

 

1 kW

2 kW

 

 

 

3 kW

 

P/L (ms)

 

0.1

0.1

0.1

0.2

0.4

0.7

1.5

2.0

 

 

 

 

 

 

 

 

28 kHz:

28F-8

28F-18

 

 

28F-24H

 

PRR

 

600

600

600

375

187

110

50

38

 

 

 

 

 

 

50 kHz:

50B-9B

50B-12

 

 

50F-24H

6.

Picture Advance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

88 kHz:

88B-8

88B-10

 

 

88B-126H

 

Freeze, 1/16, 1/8, 1/4, 1/2, 1/1, 2/1 scan lines/tx

 

 

 

 

 

 

 

 

 

200 kHz:

200B-8B

200B-8B

 

 

200B-12H

7. Data Interface (NMEA0183) *Optional sensor required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$- -RMA, $- -RMB, $- -RMC, $- -GLL, $- -VTG, $- -VHW,

 

 

 

 

 

 

 

 

 

 

 

 

$- -MTW, - -XTE, $- -BWC - -: Any talker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display Unit CV-291/CV-292

 

 

 

 

 

 

 

 

 

 

 

Display Unit

 

 

 

 

 

 

 

 

 

 

447

17.6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

NAV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

 

 

 

 

 

 

 

5 m

 

 

 

 

 

 

 

 

 

291

11.5"

 

3.5"

1.7"

 

293

 

 

 

 

GPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VDC

VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

319 12.6"

 

 

 

 

 

 

 

 

 

for10.5 - 20.0

for18.0 - 40.0

 

Rectifier

 

 

Speed/Temp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PR-62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m m

 

 

 

 

 

 

ST01-MSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

0, 3.5

0, 3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- -

 

 

 

 

 

 

T-02MSB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03S9148

02S4094

 

 

 

 

 

 

 

 

 

 

 

 

370

14.6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight: 12 kg 26.5 lbs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

126

5.0" (160

6.3")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4– ø12

 

 

 

 

115/230 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.5 - 20.0 VDC or

Transducers (28/38*/50/88/200 kHz)

 

 

 

 

 

 

 

3.9")

 

 

 

 

 

4.7")

 

 

18.0 - 40.0 VDC

 

Select one for FCV-291

 

 

 

 

Option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting dimensions

(100

 

 

 

 

 

(120

 

 

(Specify when ordering)

Select two for FCV-292

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* 38 kHz Transducer to be procured by user

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

FURUNO U.S.A., INC.

FURUNO DANMARK AS

0009XN Printed in Japan

Camas, Washington, U.S.A.

Hvidovre, Denmark

 

 

Phone: +1 360-834-9300 Telefax: +1 360-834-9400

Phone: +45 36 77 45 00 Telefax: +45 36 77 45 01

 

FURUNO (UK) LIMITED

FURUNO NORGE A/S

 

Denmead, Hampshire, U.K.

Ålesund, Norway

 

Phone: +44 2392-230303 Telefax: +44 2392-230101

Phone: +47 70 102950 Telefax: +47 70 127021

 

FURUNO FRANCE S.A.

FURUNO SVERIGE AB

 

Bordeaux-Mérignac, France

Västra Frölunda, Sweden

 

Phone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01

Phone: +46 31-709 89 40 Telefax: +46 31-49 70 93

 

FURUNO ESPANA S.A.

FURUNO SUOMI OY

 

Madrid, Spain

Helsinki, Finland

Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97

Phone: +358 9 341 7570 Telefax: +358 9 3417 5716

Page 4
Image 4
Furuno FCV-291/292 manual Specifications of FCV-291/FCV-292