Gardena 5000 S Cleaning, Storage, Trouble-Shooting, Technical Data, Flushing the Pump, Safety and

Models: 5000 S

1 6
Download 6 pages 54.11 Kb
Page 4
Image 4
5. Cleaning

G

5. Cleaning

The pumps are virtually maintenance-free.

G

Attention!Repairs on electrical parts should only be done by our GARDENA Service Centres.

Flushing the Pump:

Cleaning the suction base and turbine:

9

6

8

After having pumped chlorinated swimming pool water or other liquids leaving residues, the pump should be rinsed with clear water.

Warning! Electric shock!

ARisk of injury due to electric shock.

V Disconnect the pump from the mains before clean- ing the suction base and turbine.

If you have any problems with your Pump, please contact our Service.

7. Storage

Frost-free storageStore the pump away from frost before the first frost sets in.

1.Unscrew the 3 Phillips screws 8 and pull the suction base 6 off the pump.

2.Clean the suction base 6 and the turbine 9.

3.Reinstall the suction base 6 and screw in the Phillips screws 8.

For safety reasons a damaged turbine 9 can only be ex- changed by the GARDENA Service Centre.

6. Trouble-Shooting

Problem

Probable cause

Remedy

 

 

 

Pump is running,

Air cannot escape, since

v Open pressure line

but doesn’t deliver.

pressure line is closed.

(e.g. kinked pressure pipe).

 

 

 

 

Air locks in the suction base.

v Wait for max. 60 seconds

 

 

until the pump deaerates

 

 

automatically over the vent

 

 

valve. If necessary, switch

 

 

off and start it again.

 

 

 

 

Turbine clogged.

v Disconnect plug and clean

 

 

turbine (see 5. Cleaning).

 

 

 

 

When starting the pump,

v Submerge pump deeper.

 

water height falls below the

 

 

min. water level.

 

 

 

 

Pump doesn’t start or

Thermal overload switch has

v Disconnect plug and clean

suddenly stops during

switched the pump off due

turbine (see 5. Cleaning).

operation.

to overheating.

Observe max. media temper-

 

 

ature of 35 °C.

 

 

 

 

No power.

v Check fuses and electric

 

 

connections.

 

 

 

 

Dirt particles are jammed

v Disconnect plug and clean

 

in the suction base.

suction base (see 5. Clean-

 

 

ing).

 

 

 

Pump runs, but output

Suction base is clogged.

v Disconnect plug and clean

suddenly decreases.

 

suction base (see 5. Clean-

 

 

ing).

 

 

 

8. Technical Data

Type

5000 S (Art. No. 1778)

Rated power

200 W

 

 

Max. delivery capacity

5,000 l/h

 

 

Max. pressure

0.5 bar

 

 

Max. delivery height

5 m

 

 

Max. submersion depth

9 m

 

 

Flat suction down to approx.

5 mm

 

 

Contaminated water with

 

particle size of max.

5 mm

 

 

Power cable

10 m H05 RNF

 

 

Pump connection

38 mm (1 1/2 ) / 25 mm (1) graduated nipple,

 

option GARDENA Water hose Plug-in-system

 

 

Min. water level for operation

45 mm

 

 

Weight approx.

4.0 kg

 

 

Max. media temperature

35 °C

 

 

Mains voltage /

 

mains frequency

230 V / 50 Hz

 

 

Min.cut-in height

380 mm

 

 

Min./max. cut-out height

100 mm / 140 mm

 

 

1)

46 dB(A)

Noise level L WA

1) Measuring method according to EN 60335 -1

Cut-in / Cut-out height

 

The cut-in and cut-out height varies.

 

The residual water depth (draining in the flat position down

 

to approx. 5 mm) is only reached during manual operation

 

(see 4. Operation).

Safety and

The GARDENA Submersible Pump is manufactured in accordance

Approval

with the current electrical safety regulations of the Appliance

 

Safety Law (GSG) and inspected by the TÜV (German institution

 

for technical surveillance).

14

15

Page 4
Image 4
Gardena 5000 S Cleaning, Storage, Trouble-Shooting, Technical Data, Flushing the Pump, Cut-in / Cut-out height, Safety and