G
5. Cleaning
The pumps are virtually
G
Attention!Repairs on electrical parts should only be done by our GARDENA Service Centres.
Flushing the Pump:
Cleaning the suction base and turbine:
9 | 6 | 8 |
After having pumped chlorinated swimming pool water or other liquids leaving residues, the pump should be rinsed with clear water.
Warning! Electric shock!
ARisk of injury due to electric shock.
V Disconnect the pump from the mains before clean- ing the suction base and turbine.
If you have any problems with your Pump, please contact our Service.
7. Storage
1.Unscrew the 3 Phillips screws 8 and pull the suction base 6 off the pump.
2.Clean the suction base 6 and the turbine 9.
3.Reinstall the suction base 6 and screw in the Phillips screws 8.
For safety reasons a damaged turbine 9 can only be ex- changed by the GARDENA Service Centre.
6. Trouble-Shooting
Problem | Probable cause | Remedy |
|
|
|
Pump is running, | Air cannot escape, since | v Open pressure line |
but doesn’t deliver. | pressure line is closed. | (e.g. kinked pressure pipe). |
|
|
|
| Air locks in the suction base. | v Wait for max. 60 seconds |
|
| until the pump deaerates |
|
| automatically over the vent |
|
| valve. If necessary, switch |
|
| off and start it again. |
|
|
|
| Turbine clogged. | v Disconnect plug and clean |
|
| turbine (see 5. Cleaning). |
|
|
|
| When starting the pump, | v Submerge pump deeper. |
| water height falls below the |
|
| min. water level. |
|
|
|
|
Pump doesn’t start or | Thermal overload switch has | v Disconnect plug and clean |
suddenly stops during | switched the pump off due | turbine (see 5. Cleaning). |
operation. | to overheating. | Observe max. media temper- |
|
| ature of 35 °C. |
|
|
|
| No power. | v Check fuses and electric |
|
| connections. |
|
|
|
| Dirt particles are jammed | v Disconnect plug and clean |
| in the suction base. | suction base (see 5. Clean- |
|
| ing). |
|
|
|
Pump runs, but output | Suction base is clogged. | v Disconnect plug and clean |
suddenly decreases. |
| suction base (see 5. Clean- |
|
| ing). |
|
|
|
8. Technical Data
Type | 5000 S (Art. No. 1778) |
Rated power | 200 W |
|
|
Max. delivery capacity | 5,000 l/h |
|
|
Max. pressure | 0.5 bar |
|
|
Max. delivery height | 5 m |
|
|
Max. submersion depth | 9 m |
|
|
Flat suction down to approx. | 5 mm |
|
|
Contaminated water with |
|
particle size of max. | 5 mm |
|
|
Power cable | 10 m H05 RNF |
|
|
Pump connection | 38 mm (1 1/2 ”) / 25 mm (1”) graduated nipple, |
| option GARDENA Water hose |
|
|
Min. water level for operation | 45 mm |
|
|
Weight approx. | 4.0 kg |
|
|
Max. media temperature | 35 °C |
|
|
Mains voltage / |
|
mains frequency | 230 V / 50 Hz |
|
|
380 mm | |
|
|
Min./max. | 100 mm / 140 mm |
|
|
1) | 46 dB(A) |
Noise level L WA | |
1) Measuring method according to EN 60335 | |
|
|
The | |
| The residual water depth (draining in the flat position down |
| to approx. 5 mm) is only reached during manual operation |
| (see 4. Operation). |
Safety and | The GARDENA Submersible Pump is manufactured in accordance |
Approval | with the current electrical safety regulations of the Appliance |
| Safety Law (GSG) and inspected by the TÜV (German institution |
| for technical surveillance). |
14 | 15 |