Pump motor runs, but quantity

Leak on the suction side.

Repair the leak.

delivered or pressure fall away

Too little water on intake side.

Throttle the pump on the

suddenly.

 

pressure side so that the flow

 

 

 

 

quantity on the suction side

 

 

is governed by that on the

 

 

pressure side.

 

 

 

 

Suction filter or non-return valve

Clean the suction filter/non-

 

blocked.

return valve.

 

 

 

Pump switches on and off too

Boiler diaphragm is damaged.

Have the boiler diaphragm

frequently.

 

replaced by GARDENA

 

 

Service.

GB

Top up the air in the storage tank:

Pressure in the boiler is too low. Top up the air in the storage tank.

The pressure in the storage tank must be approx. 1.5 bar.

To top up the air, an air pump/tyre pump with a pressure gauge (manometer) is required.

1.

Unscrew the protective cover .

2.

Attach the air pump/tyre pump to the boiler valve and pump

 

air in until the air pump/tyre pump pressure gauge shows

 

approx. 1.5 bar.

3.

Screw the protective cover back on.

CAUTION !

Work on the electrical parts must only be carried out by

 

GARDENA Service Centres.

If any other faults occur, please contact GARDENA Service.

8. Accessories

GARDENA Suction Hoses

Kink- and vacuum-resistant, sold by the metre with 19 mm (3/4”)

 

or 25 mm (1”) diameter without fittings or in fixed length,

 

complete with fittings.

 

 

 

 

GARDENA Suction Hose Fittings

 

Art. no. 1723/1724

 

 

 

GARDENA Suction Filter

To equip suction hoses with

Art. no. 1726/1727/1728

 

Backflow Preventer sold by the metre.

 

 

 

GARDENA

Recommended for pumping

Art. no. 1730/1731

Pump Preliminary Filter

sandy water.

 

 

 

 

GARDENA

For vacuum-resistant connection

Art. no. 1729

Bore Hole Suction Hose

of the pump to boreholes or pipe

 

 

networks. Length 0.5 m. With 33.3 mm

 

(G1) female thread at both ends.

 

17

Page 8
Image 8
Gardena D-89070 Ulm operating instructions Accessories