To device
Fuse Block Example

Connecting the Power/Data Cable to Power

1.Use a test light or a voltmeter to determine the polarity of the voltage source.

2.Connect the red (+ or positive) wire to the positive voltage terminal. (If you use the fuse block on the boat, route the positive connection through the fuse, as shown on the diagram.)

3.Connect the black (- or ground) wire to the negative voltage terminal.

4.Install or check the 3 A fuse (in the in-line fuse holder, or on the fuse block of the boat).

Connecting the Power/Data cable to a NMEA 0183 Device (Optional)

3 A fuse

Boat ground

+

-

To 10–32 Vdc boat supply

3A2A +

You can connect the GPSMAP 700 series chartplotter to other NMEA 0183-compatible

equipment, such as a DSC or AIS device. Refer to the wiring diagram for connecting the chartplotter to NMEA 0183-compatible devices.

GPSMAP 700

Fuse

series

3 A

chartplotter

 

 

>

 

>

+

Wire color

Red (power) Black (ground)

Blue (out)

Brown (in)

Battery -

 

10–32 Vdc

Wire function

Power

 

NMEA 0183-compatible

Power ground

 

 

NMEA Ground

 

 

device

NMEA Rx/A (+) >

 

 

 

 

 

 

NMEA Tx/A (+)

 

 

>

 

 

Wiring a GPSMAP 700 Series Chartplotter to a Standard NMEA 0183 Device

To connect the power/data cable to a NMEA 0183 device:

1.For Garmin devices, the ground (black) wires serve as NMEA 0183 ground and must be attached together or on the same terminal as the

NMEA 0183 ground on your NMEA 0183 device. Refer to the wiring diagram of your NMEA 0183 device for wire identification.

2.Connect the blue (NMEA 0183 port 1 out) wire from the GPSMAP 700 power/data cable to the NMEA 0183 in (or Rx/A +) wire from the NMEA 0183 device, and the brown (NMEA 0183 port 1 in) wire to the NMEA out (or Tx/A +) wire from the NMEA 0183 device.

3.Repeat step 2 using the gray (NMEA 0183 port 2 out) and violet (NMEA 0183 port 2 in) wires for an additional NMEA 0183 device.

4.Set the serial port (or ports) on the chartplotter to use NMEA 0183 data (standard or high-speed). See the GPSMAP 700 Series Owner’s Manual for more information.

Connecting the Power/Data Cable to a Lamp or to a Horn (Optional)

The GPSMAP 700 series chartplotter can be used with a lamp, a horn, or both, to sound or flash an alert when the chartplotter displays a message. The alarm does not need to be wired for the chartplotter to function. The alarm circuit switches to a low-voltage state when the alarm sounds. The maximum current is 100 mA, and a relay is needed to limit the current from the chartplotter to 100 mA. To manually toggle visual and audible alerts, install single-pole, single-throw switches.

 

+

Battery

-

 

Wire

10–35 Vdc

 

Fuse

Color

 

 

3 A

Red (power)

 

 

GPSMAP 700 series

Black (gnd)

 

 

chartplotter

 

 

 

 

 

 

 

 

Horn

 

Yellow (alarm)

Relay

Lamp

 

100 ma max

 

 

coil current

 

Wiring to a Lamp, a Horn, or Both

 

 

GPSMAP 700 Series Installation Instructions