Brine Valve PN 3020511
Thank you for choosing the GE Safety Brine Valve. For a complete water conditioner system, a brine valve is indispensable for system protection and regeneration, as well as ensuring the best water conditions.
The innovative design of the Brine Valve provides safe and reliable performance, and is suitable for household and commercial conditioner systems. This manual will help you better understand the structure and properties of the valve and will guide you through the installation.
We urge you to read this manual carefully and refer to it any time a malfunction occurs. The Troubleshooting Table highlights minor problems that you can correct yourself.
Overview
The brine valve is suitable for household use. For a water conditioner system, the brine valve has two principal functions:
Air Check function - During system regeneration or a slow rinse period, the brine valve prevents air from being pulled into the resin tank, thereby ensuring the system’s performance.
Refill Protection -
Product Features
Installation Manual
•Unique mechanical structure developed according to scientific principles providing the best reliability.
•Highly expandable interface with replacement fittings, to coordinate different uses of the control valve.
•Adjustments are designed for ease of use and fast set- up.
•Flow control is regulated by the body. Brine valve is suitable for most water conditioning systems.
Specifications
Dimensions: |
|
32" high unit: | 3.2" L x 2.8" W x 27.38" H |
| (80 mm x 71 mm x 695 mm) |
Rated Pressure: | 20 - 120 psi (0.14 - 0.83 MPa) |
Temperature Range: | 34 - 140°F (1 - 60°C) |
Used Media: | Clean municipal water or |
| brine |
Max. Refill Water FLow: | 1.2 GPM (4.5 L/m) |
Max. Brine Flow: | 1.0 GPM (3.7 L/m) |
Materials: |
|
Main Valve: | ABS & PE |
Seal: | Chlorine/Chloramines |
| resistant silicone rubber |
Regenerant Tube Connection
The brine valve is compatible with a 3.5" (90 mm) GE brine well, see Figure 1. The regenerant tube links the control valve and the brine valve. Place one end of the right angle elbow through the hole of the brine well. Slide the nut, retaining sleeve and plastic gripper over the regenerant tube. Insert the inner tube support and connect the regenerant tube to the elbow. Finally, connect the other end of the regenerant tube to the control valve.
Figure 1
•Positive automatic opening and closing of the valve by using vacuum or pressure.