Generator AC Connection System
A
NOTICE Neutral is not bonded to ground at generator.
NOTICE Generator must be used with only an UL approved transfer switch that is compatible with the generator.
WindingPower
33Neutral
22
120V
Circuit120V
Breaker
11
44
240V
NOT for
REPRODUCTION | 11 | ||
22 | 33 | 44 | |
|
| Circuit | |
|
| Breaker | |
Neutral | Line 2 | Line 1 |
0
Ground
Grounding the Generator
The home generator must be installed as part of a system that includes a listed transfer switch, with neutral to ground bonding at the transfer switch in accordance with installation instructions. Unless mandated by local code, additional grounding to earth at the generator is not required. Any grounding at generator must use metal piercing lock washers (or equal), UL listed terminals installed per terminal supplier’s instructions, and comply with national electrical codes and local requirements.
26