Installation Checklist - GE Home Generator Systems

Proper installation of the home generator requires the completion of the following tasks:

Carbon Monoxide (CO) Detector/ Smoke Detector

 

 

Carbon Monoxide (CO) detector(s) installed and in working

Operation

order.

 

 

 

 

 

 

 

Smoke detector(s) installed and in working order.

Cold weather kit is installed in temperatures below XX°F

Placement

 

 

 

(5°C). See Cold Weather Kit.

 

 

 

Correct battery type is installed and fully charged. See

Required permits have been obtained.

 

 

Final Installation Considerations.

Generator placed in an area free from Carbon Monoxide

Generator engine oil level is at full mark. See Final

(CO) buildup. See Placement of Standby Generator to

Installation Considerations.

Reduce the Risk of Carbon Monoxide Poisoning.

Circuit breaker is in the ON position.

Generator placed in an area compliant to NFPA 37. See

Utility was shut off to test the operation of generator and

Placement of Standby Generator to Reduce the Risk of

Fire.

 

 

 

transfer switch. Note any fault codes and make corrections

Generator placed in an area free from water damage. See

as required.

AC Voltage Output___________________________.

Other General Location Guidelines.

 

Generator placed in an area free from utility and other

Frequency Output___________________________.

home systems. See Other General Location Guidelines.

 

Generator placed in a debris free zone. See Other General

 

Location Guidelines.

 

 

REPRODUCTION

Generator placed on flat ground with provisions for water

Owner Information

drainage.See Other General Location Guidelines.

Name:______________________________________________

Fuel

 

 

 

Address: ___________________________________________

Generator is connected to fuel source with steel flexible

___________________________________________________

fuel line, has no fuel leaks and conforms to local codes. See

Phone/e-mail:________________________________________

The Gaseous Fuel System.

 

 

Unit Information

Proper fuel pressure has been measured with all gas

 

NOT

 

Generator Model:_____________________________________

appliances operating. See The Gaseous Fuel System.

Fuel system has been configured for the proper fuel

Generator Serial Number:______________________________

supply: Natural gas (NG) or liquefied petroleum ( LP). See

 

Fuel Conversion.

 

 

 

nstalling Contractor Information

Fuel type: (circle one)

G

LP

 

Name:______________________________________________

Fuel pipe size used: (circle one)

3/4” 1” 1-1/4” 1-1/2”

Address: ___________________________________________

See NFPA 54.

 

 

 

___________________________________________________

Fuel pressure at fuel inlet port withforgenerator on and at

Phone/FAX:__________________________________________

full load and all gas appliances turned on and operating

____________________.

 

 

 

 

Electrical

 

 

 

Electrician: __________________________________________

Generator neutral is connected to Automatic Transfer

Signature:___________________________________________

Switch. See Generator AC Connection System.

 

Generator is grounded. See Grounding the Generator and

Plumber: ___________________________________________

NFPA 70,NEC.

 

 

 

Signature: _ _________________________________________

Generator is connected to the transfer switch with the

Inspector Information

specified wiring. See Utility Circuit Connection and

Transfer Switch Communication.

 

Name:______________________________________________

Generator is connected to the transfer switch with the

Address:_ ___________________________________________

specified wiring. #18AWG twisted pair wiring from the

___________________________________________________

generator control panel to the transfer switch is installed

Title:_______________________________________________

in a separate conduit from high voltage wires unless

Inspection Date:______________________________________

the insulation rating on all wiring is rated for 600V See

Transfer Switch Communication.

 

 

Dipswitches in most transfer switches must be set to

This generator has been installed per the manufacturer’s

instructions:

correspond to the wattage of the generator. See Transfer

Installing Contractor Signature: _______________________________

Switch Operator/Installation Manual.

 

 

Date:_____________________________________________________

 

 

 

 

9