[] RECONNECTING GAS

Listed connector ANSI Z21.24 / CSA 6.10

APPLYPiPECOMPOUND

TOALL MALETHREADS.

 

118" NPT PIPE

NEWMETAL

PLUG FOR GAS

FLEXIBLEGAS

INLET PRESSURE

LINECONNECTOR

 

ADAPTER

SHUT-OFF

 

3/8"

NPT

ELBOW

 

 

PIPE SIZE

ITEMSNOT SUPPLIED

AT LEAST 1/2"

Note: The connector and fittings are designed for use onty on the original insta[tation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of ]rease, oi[ and thread sealant.

Caution: Use adapters as shown. Connector nuts must not be connected directly to pipe threads.

TIGHTEN ALL CONNECTIONS

USINGTWO ADJUSTABLE WRENCHES.

DO NOT OVERTORQUE GAS CONNECTIONS!

LEAK TEST

[,_ WARNING - NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS.

APPLYPIPECOMPOUND

TO THEADAPTERAND

DRYERGAS INLET.

OPEN

GASVALVE.

TIGHTEN THE FLEXIBLE

GAS LINE USING TWO

ADJUSTABLE WRENCHES.

Check alt connections for leaks with soapg solution or equivalent. Apply soap solution. Leak test solution must not contain ammo- nia which could cause damage to the brass fittings. If leaks are found, close valve, retighten the joint, and repeat the soap test.