Installation Instructions

Installation Instructions

Important electrical safety–read carefully

Important Notes

Installer: Leave these instructions with the appliance.

Owner: Keep these instructions for future use.

For personal safety, this air conditioner must be properly grounded.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

Follow National Electrical Code (NEC) or local codes and ordinances.

Important electrical safety–read carefully CAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems— consult a qualified electrician.

Electrical Requirements

115V., 15 Amp.

The 115-volt models require a 115/120- volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.