GE Appliances

AZ28E12D – GE Zoneline® Deluxe Series Cooling and Electric Heat Unit

Wall Case Dimensions

Maximum Cord Extension (in inches)

A

C

21

58

B

Electrical Wiring

All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.

Note: Aluminum wiring may pose special problems – consult a qualified electrician.

Grille Options

Stamped Aluminum Grille – RAG60

Exterior Architectural Louvers Durable Polycarbonate:

RAG61 or RAG64 (Beige)

RAG63 or RAG66 (Bittersweet)

RAG62 or RAG65 (Maple)

RAG67 (Extruded Aluminum)

Retrofit Kits:

RAK901L – Wall Case Insulation for use with heat pumps. RAK40 – Deflector Kit to adapt chassis for use with existing

RAB71 Wall Sleeve

Heavy-gauge galvanized steel, with insulation. A – 42", B – 13-3/4", C – 16"

RAB77 Wall Sleeve

Molded SMC fiberglass-reinforced polyester compound. A – 42-1/8", B– 13-7/8", C – 16-1/4

Wall Opening Dimensions

Add 1/4" to A and C dimensions for all cut-out size. RAB71 16-1/4" Min. H x 42-1/4" Min. W

RAB71 available in 16", 24", 28" and 31" depths RAB77 16-1/2" Min. H x 42-3/8" Min. W

exterior architectural louvered grilles.

Ducted Applications

2800 and 3800 series can be used with ductwork to heat or cool more than one room. RAK6052 Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied to right or left of adaptor. Locally fabricated ductwork

230/208 Volt Line Cord Connected Units

 

 

 

 

Min. Circuit

Line Cord

Electric Heat

Electric

Electric

Protection

Kit

(Btuh)

Heater Watts

Heat Amps

(Amps)

RAK3153

8,600/7,100

2,550/2,090

11.6/10.6

15

RAK3203

11,700/9,600

3,450/2,820

15.5/14.1

20

RAK3303

17,000/13,900

5,000/4,090

22.3/20.3

30

 

 

 

 

 

230/208 Volt Sub-Base Connected Units

 

 

 

 

 

 

Min. Circuit

 

Electric Heat

Electric

Electric

Protection

Sub-Base

(Btuh)

Heater Watts

Heat Amps

(Amps)

RAK204D15P

8,600/7,100

2,550/2,090

11.6/10.6

15

RAK204D20P

11,700/9,600

3,450/2,820

15.5/14.1

20

 

 

 

 

 

RAK204D30P

17,000/13,900

5,000/4,090

22.3/20.3

30

 

 

 

 

 

Specification Revised 4/06

may be added to extend to maximum recommended distance of 15 feet.

Electrical Connection

230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers Design Data Manual for electrical connection information including use of sub-base for direct connected units. Installation must comply with local electrical codes and regulations.

Power Connection kits required on all Zoneline chassis.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

390508

Page 1
Image 1
GE AZ28E12DAB dimensions Wall Case Dimensions, Electrical Wiring, Grille Options, Retrofit Kits, RAB71 Wall Sleeve