GE Appliances
AZ38H12D – GE Zoneline® Deluxe Series Heat Pump Unit
Wall Case Dimensions | Maximum Cord Extension (in inches) |
A
C
21 | 58 |
B
Electrical Wiring
All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
Note: Aluminum wiring may pose special problems – consult a qualified electrician.
Grille Options
Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 or RAG64 (Beige) | RAG63 or RAG66 (Bittersweet) |
RAG62 or RAG65 (Maple) | RAG67 (Extruded Aluminum) |
Retrofit Kits:
RAK901L – Wall Case Insulation for use with heat pumps. RAK40 – Deflector Kit to adapt chassis for use with existing
RAB71 Wall Sleeve
RAB77 Wall Sleeve
Molded SMC
Wall Opening Dimensions
Add 1/4" to A and C dimensions for all
RAB71 available in 16", 24", 28" and 31" depths RAB77
exterior architectural louvered grilles.
Ducted Applications
2800 and 3800 series can be used with ductwork to heat or cool more than one room. RAK6052 Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied to right or left of adaptor. Locally fabricated ductwork
230/208 Volt Line Cord Connected Units
|
|
|
| Min. Circuit |
Line Cord | Electric Heat | Electric | Electric | Protection |
Kit | (Btuh) | Heater Watts | Heat Amps | (Amps) |
RAK3153 | 8,600/7,100 | 2,550/2,090 | 11.6/10.6 | 15 |
RAK3203 | 11,700/9,600 | 3,450/2,820 | 15.5/14.1 | 20 |
RAK3303 | 17,000/13,900 | 5,000/4,090 | 22.3/20.3 | 30 |
|
|
|
|
|
230/208 Volt |
|
| ||
|
|
|
| Min. Circuit |
| Electric Heat | Electric | Electric | Protection |
(Btuh) | Heater Watts | Heat Amps | (Amps) | |
RAK204D15P | 8,600/7,100 | 2,550/2,090 | 11.6/10.6 | 15 |
RAK204D20P | 11,700/9,600 | 3,450/2,820 | 15.5/14.1 | 20 |
|
|
|
|
|
RAK204D30P | 17,000/13,900 | 5,000/4,090 | 22.3/20.3 | 30 |
|
|
|
|
|
Specification Revised 4/06
may be added to extend to maximum recommended distance of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers Design Data Manual for electrical connection information including use of
Power Connection kits required on all Zoneline chassis.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
390520