GE Appliances

AZ58H12D – GE Zoneline® Premium Series Heat Pump Unit

Wall Case Dimensions

Maximum Cord Extension (in inches)

A

C

21

58

B

Electrical Wiring

All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.

Note: Aluminum wiring may pose special problems – consult a qualified electrician.

Grille Options

Stamped Aluminum Grille – RAG60

Exterior Architectural Louvers Durable Polycarbonate:

RAG61 or RAG64 (Beige)

RAG63 or RAG66 (Bittersweet)

RAG62 or RAG65 (Maple)

RAG67 (Extruded Aluminum)

Retrofit Kits:

RAK901L – Wall Case Insulation for use with heat pumps. RAK40 – Deflector Kit to adapt chassis for use with existing

RAB71 Wall Sleeve

Heavy-gauge galvanized steel, with insulation. A – 42", B – 13-3/4", C – 16"

RAB77 Wall Sleeve

Molded SMC fiberglass-reinforced polyester compound. A – 42-1/8", B– 13-7/8", C – 16-1/4

Wall Opening Dimensions

Add 1/4" to A and C dimensions for all cut-out size. RAB71 16-1/4" Min. H x 42-1/4" Min. W

RAB71 available in 16", 24", 28" and 31" depths RAB77 16-1/2" Min. H x 42-3/8" Min. W

exterior architectural louvered grilles.

Electrical Connection

230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers Design Data Manual for electrical

230/208 Volt Line Cord Connected Units

 

 

 

 

Min. Circuit

Line Cord

Electric Heat

Electric

Electric

Protection

Kit

(Btuh)

Heater Watts

Heat Amps

(Amps)

RAK3153

8,600/7,100

2,550/2,090

11.6/10.6

15

RAK3203

11,700/9,600

3,450/2,820

15.5/14.1

20

RAK3303

17,000/13,900

5,000/4,090

22.3/20.3

30

 

 

 

 

 

230/208 Volt Sub-Base Connected Units

 

 

 

 

 

 

Min. Circuit

 

Electric Heat

Electric

Electric

Protection

Sub-Base

(Btuh)

Heater Watts

Heat Amps

(Amps)

RAK204D15P

8,600/7,100

2,550/2,090

11.6/10.6

15

RAK204D20P

11,700/9,600

3,450/2,820

15.5/14.1

20

 

 

 

 

 

RAK204D30P

17,000/13,900

5,000/4,090

22.3/20.3

30

 

 

 

 

 

Specification Revised 4/06

connection information including use of sub-base for direct connected units. Installation must comply with local electrical codes and regulations.

Power Connection kits required on all Zoneline chassis.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

390566

Page 1
Image 1