Rugged Dome Installation Manual Mounting the Unit
1038346B / February 2003 9
2.1 SURFACE-MOUNTING THE HOUSING To surface-mount the housing, see Figure 8 and perform the following.
Mounting
surface
Anchors
Outer plate
Inner plate
M4x20 truss-head
tapping screws
(3)
M4x12 pan-head
double-washer
screws (3)
(through housing
base)
Figure 8. Surface-mounting the housing
Note: Feed the cables through the mounting surface, plates, and housing at the
appropriate time depending on whether you are using the flying lead and whether the cable
is external or internal to the mounting surface.
To prepare the mounting surface perform the following.
1) Position the outer plate on the mounting surface at the installatio n
location.
2) Trace the position of the mounting holes.
3) If you are using the back cable entry, trace its outline.
4) Drill the outlined mounting holes.