DSXH47GG

GE® 5.8 Cu. Ft. Extra-Large Capacity Frontload Gas Dryer

Special Installation Requirements:

Stacked Installation:

Brackets for stacking dryer are included as part of the dryer, DSXH43EF/GF. See dryer Use & Care for details.

Bracket for stacking dryer, DSXH47EG/GG, order Pub. No. 14-A026 or STACKIT1WW at additional cost.

Undercounter installation:

The WSSH300G and DSXH47EG/GG require a custom-sized countertop (36 inches to the underside of the countertop). No special washer or dryer top is required.

Alcove or Closet Installation:

If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.

The dryer MUST be exhausted to the outside.

Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear

Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".

Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

The dryer MUST be exhausted to the outdoors.

The installation must conform with the local codes, or in the absence of

local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearance other than Alcove or Closet Installations:

• Minimum clearances to combustible surfaces 0" both sides, 3" rear.

For more information on venting kits and accessories, please call 1-800-GE-CARES.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

Specification Revised 5/09