0150-0198H 37 DVMRe Triplex eZ
q Main Menu Record Auto Delete Mode
The ADM feature prevents the unit from displaying or archiving any search results that are more than
thirty days old. This feature may be required by law in some jurisdictions. Choose from 1 to 99 days or
Off. The default setting is Off.
ADM will change. Are you sure?
Message
ADM Setting
99 Days
Yes
3.10 Alarms
Use this menu to configure the alarm handling features of the unit.
Caution! The DVMRe Triplex eZ’s primary function is to furnish
video multiplexing and recording with a multiscreen display.
Although the unit has alarm handling and motion detection
functions, these are considered secondary features. This unit
should not be the only alarm device on site.
q Main Menu Alarms Input Configuration
Configure the alarm inputs as either Normally Open or Normally Closed.
Configure inputs as follows.
Normally Open Zero Potential Relay Contact: Configure in menu as
Normally Open.
Normally Closed Zero Potential Relay Contact: Configure in menu
as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
TTL Active Low: Configure in menu as Normally Open.
Open Collector Active On: Configure in menu as Normally Open.
Open Collector Active Off: Configure in menu as Normally Closed.
q Main Menu Alarms Alarm Latch
This feature determines how the unit latches alarm conditions.
Selecting from the following options.
Latched: The alarm is activated until it is silenced and acknowledged
by the user.
Latched
Transparent
Timed Out
Input Configuration
Alarm Latch
Enable / Disable
Alarm History
Link to a Macro
Buzzer Setup
Notification
Archive Alarms