0150-0198H 38 DVMRe Triplex eZ
Transparent: The alarm is active only while receiving alarm input.
The alarm condition is canceled when the alarm input ceases.
Timed Out: The alarm condition is latched for the amount of time selected in this menu, then it is
automatically silenced and acknowledged. If the alarm input exceeds the duration specified in this
menu, the unit silences and acknowledges the alarm when the alarm input ceases. Select the timeout
duration, the range is from 1 to 250 seconds.
Transparent alarms cannot be silenced and acknowledged. If transparent mode is preferred, but the
ability to silence and acknowledge alarms is desired, select Timed Out and set the Alarm Timeout to
two seconds.
q Main Menu → Alarms → Enable / Disable
Use this menu to Enable or Disable the alarm inputs.
Select from the following:
• Individual Enable: Allow the user to access the Alarm
Enable submenu, and enable or disable alarm inputs on
a per camera basis.
• Enable All
• Disable All
Rotate the Jog to navigate, and the Shuttle to change
the values.
Save changes and exit the menu: Select [OK], then press the
Enter button.
Exit the menu without making changes: Press the Menu
button, or select [CANCEL], then press the Enter button.
q Main Menu → Alarms → Alarm History
Use this window to view a list of the 100 most recent alarms.
Alarms are displayed 10 at a time. Rotate the Jog to scroll
through the alarms.
Information displayed in this window is:
• The alarms number in the list.
• The date of the alarm (month and day).
• The time of the alarm (hours, minutes, and seconds).
The number of the camera input in alarm.
Enable All
Disable All
Individual Enable
Alarm History Box
001- 02/04 18:40:32 16
002- 02/15 12:00:10 11
003- 02/28 10:10:20 08
:
:
010- 03/15 05:12:16 04
[OK]