•Alarms included: low inlet pressure, high amp draw, high / low pH
1.5Specifications for
1.5.1Feed Water Requirements
| Table 1.1 |
| Feed Water Requirements |
|
|
Temperature | 35° - 77°F (2° - 25°C) Not to exceed |
| 85°F (29°C) unless specifically |
| designed for higher temperatures |
|
|
Inlet Pressure | Minimum: 30 psig (2.1 barg) |
| Maximum: 60 psig (4.1 barg) |
|
|
Chlorine | For Osmo HR(PA) membrane ele- |
(continuous feed) | ments: 0 ppm |
|
|
Operating pH | Soft water [less than 1 grain per gal- |
| lon: 3.0 - 10.0 (gpg) or 17 mg/L hard- |
| ness], acceptable pH: 5.5 - 6.0 |
|
|
5 micron HYTREX cartridge | |
| (part number on machine label) |
|
|
Inlet Connections | |
|
|
1.5.2Permeate (Product Water) Flow Rate
Stated on the serial number label (assumes no permeate back pressure, 2000 mg/L TDS maximum feed concentration, and rated temperature).
To estimate permeate output with back pressure, use the formula below:
(Permeate Flow on Label) x [(Operating Pressure) - (Permeate Back Pressure)] Operating Pressure
Permeate Back Pressure: | Maximum: 80 psig (5.5 barg) |
Permeate Outlet: |
*FNPT: Female National Pipe Thread
7