GE GDF520PGD Drain Strip Circuits Drain Pump,  /RRVHQ RU UHPRYH WKH UDLQ 3XPS +DQJHU, ±  ±

Models: GDT550HGD GDT530PGD GDF520PGD GDF510PGD GDF540HGD

1 73
Download 73 pages 38.19 Kb
Page 62
Image 62
 /RRVHQ RU UHPRYH WKH 'UDLQ 3XPS +DQJHU

‡  VHFRQGV RII

‡  VHFRQGV RQ

7KH 'UDLQ 3XPS KDV D 7&2 ZKLFK EUHDNV WKH OLQH VLGH RI WKH FLUFXLW VKRXOG H[FHVVLYH KHDW EH GHWHFWHG RQ WKH FRQQHFWRU ,I WKLV 7&2 WULSV UHSODFH WKH GUDLQ SXPS DQG ZLUH KDUQHVV 7KH 7&2 LV SDUW RI WKH $& +DUQHVV

 5HPRYH WKH VXPS DVVHPEO\

 /RRVHQ RU UHPRYH WKH 'UDLQ 3XPS +DQJHU

 /RRVHQ FODPS RQH WLPH FODPS VKRXOG EH GLVFDUGHG  UHPRYH RU UHSODFH GUDLQ SXPS

Clamp Removal Tip: ,QVHUW D VPDOO VFUHZGULYHU LQWR WKH ³HDU´ RI WKH FODPS 0RYH WKH KDQGOH HQG RI WKH VFUHZGULYHU VLGH WR VLGH WR ORRVHQ WKH FODPS 6OLGH WKH KRVH DQG FRPSRQHQW DSDUW WKH FODPS FDQ QRZ EH UHPRYHG IURP WKH KRVH

&ULPS W\SH FODPSV ZLOO EH UHSODFHG E\ :'; &ODPS .LW

Drain Strip Circuits

Drain Pump

7KH 'UDLQ 3XPS LV D  YROW $& V\QFKURQRXV PRWRU UHVLVWDQFH RI WKH PRWRU ZLQGLQJV LV  RKPV  RU 

Notice: All Safety Shields must be reinstalled..

To remove or replace the Drain Pump

 5HPRYH SRZHU WR WKH XQLW  5HPRYH WKH GRRU

:KHQ UHSODFLQJ WKH GUDLQ SXPS FODPSV

:';  PDNH VXUH WR SRVLWLRQ WKH KRVH DQG WKH FODPS DUH ORFDWHG WR HQVXUH SURSHU FRQQHFWLRQ WKHUH LV D ORFDWRU WDE RQ WKH VXPS DQG GUDLQ SXPS DQG D ORFDWLQJ QRWFK LQ WKH HOERZ KRVH ,I QRW SRVLWLRQHG SURSHUO\ D OHDN LV OLNHO\

±  ±

Page 62
Image 62
GE GDF520PGD, GDF540HGD, GDF510PGD manual Drain Strip Circuits Drain Pump,  /RRVHQ RU UHPRYH WKH UDLQ 3XPS +DQJHU, ±  ±