OPERATION
To receive filter water, fully open cold water and pull valve stem. Allow water to flush for 3 seconds before each use. When your water needs are finished, simply turn off the cold water.
WARNING: Do not attempt to filter hot water above 100°F (37.7°C). It will damage the filter cartridge and decrease performance.
NOTE: If it is necessary to connect a portable dishwasher to your faucet, simply unscrew the aerator from the filter and attach the dishwasher according to the manufacturer’s instructions.
Filter Cartridge Replacement
1 | Turn off the water to the filtration system. Remove the old filter cartridge by using |
the finger tabs underneath the housing and turning the filter in the direction |
shown. Be sure to support the faucet and the filter housing during filter removal to avoid damage. Dispose of old cartridge.
NOTE: Some water may drip from the system during filter cartridge removal.
2 | Insert new filter cartridge into the filter housing and turn | |
stops. Slowly turn on the cold water and check for leaks. | ||
| ||
| NOTE: If leak occurs at filter, turn cartridge to make sure it is fully sealed. | |
| With the cold water fully open, pull the valve stem to begin flushing the system. | |
3 | ||
Flush new filters for 10 minutes to remove any harmless carbon fines that may be | ||
|
in the system.
Finger tabs
Performance Data
GE GXFM03C and GXFM04FBL with FXMLC Cartridge Faucet Mount Filtration System
This system has been tested according to NSF/ANSI 42 and 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
| Influent | Max. Permissible |
|
|
|
Substance | Challenge | Product Water | Reduction | Minimum | Average |
Concentration | Concentration | Requirements | Reduction | Reduction | |
Standard 42 |
|
| ≥ 50% |
|
|
Chlorine | 2.0 mg/L ± 10% |
|
| 97.5% | |
Particulates | at least 10,000 particles/mL |
| ≥ 85% |
| 99.3% |
(0.5 to < 1 ∝m) |
|
|
|
|
|
Class I |
|
|
|
|
|
Standard 53 |
|
|
|
|
|
Cysts2) | Minimum 50,000/L |
| 99.95% | 99.96% | 99.99% |
Turbidity | 11 ± 1 NTU | 0.5 NTU |
| 98.5% | 98.9% |
Lead (6.5 pH) | 0.15 mg/L ± 10% | 0.010 mg/L |
| 99.3% | 99.3% |
|
|
|
|
|
|
Lead (8.5 pH) | 0.15 mg/L ± 10% | 0.010 mg/L |
| 99.3% | 99.3% |
|
|
|
|
|
|
Lindane | 0.002 mg/L ± 10% | 0.0002 mg/L |
| 97.6% | 97.6% |
Atrazine | 0.009 mg/L ± 10% | 0.003 mg/L |
| 93.9% | 94.9% |
|
|
|
|
|
|
2) Based on the use of microspheres.
Testing was performed under standard laboratory conditions; actual performance may vary.
NOTE: Substances reduced are not necessarily in your water. Filter must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that contain filterable cysts.
Test Conditions: |
|
| Operating Requirements: | ||
| Flow Rate: 0.6 gpm (2.3 Lpm) |
| Service Flow Rate: 0.6 gpm (2.3 Lpm) | ||
| Inlet Pressure: 60 psi (4.1 bar) |
| Rated Service Life: 200 gallons (757 liters) | ||
| pH of 7.5±1 |
|
| Pressure: | |
| Temp of |
| Temperature: | ||
|
|
|
| PARTS LIST |
|
| Ref. No. | Part No. | Part Description | ||
0001 | GXFM03C | Faucet Mount Filter System (includes filter and connection hardware) | |||
|
| GXFM04FBL | Chrome Faucet Mount Filter System (including filter and connection) | ||
0002 | FXMLC | Lead/Cyst Faucet Mount Replacement Filter | |||
0999 | Use and Care/Installation Instructions |
Iowa Residents Only:
_________________________________________________________
Store or Seller’s name
_________________________________________________________
Address
_________________________________________________________
CityStateZip
_________________________________________________________
Telephone
_________________________________________________________
Seller’s signature
_________________________________________________________
Customer’s signature | Date | ||
|
|
|
|
|
|
| |
|
| State of California | |
|
| Department of Health Services | |
|
| Water Treatment Device | |
|
| Certificate Number | |
|
| 00 - 1449 |
|
|
| Date Issued: September 1, 2000 | |
|
| Date Revised: October 23, 2003 | |
|
|
|
|
|
|
|
|
| Trademark/Model Designation | Replacement Elements | |
| GE Smartwater - GXFM03C | FXMLC | |
| GE Smartwater - GXFM04FBL | FXMLC |
Manufacturer: General Electric Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity | Inorganic/Radiological Contaminants |
Cysts (protozoan) | Lead |
Turbidity |
|
Organic Contaminants |
|
Atrazine |
|
Lindane |
|
Rated Service Capacity: 200 gallons | Rated Service Flow: 0.6 gpm |
Conditions of Certification:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems claiming cyst reduction may be used on water containing cysts.
LIMITED ONE YEAR WARRANTY
• What does this warranty cover? |
|
|
| |
— Any defect in materials or workmanship in the manufactured product. |
| EXCLUSION OF IMPLIED |
| |
• What does this warranty not cover? |
|
| ||
| product exchange as provided in this Limited Warranty. Any implied warranties, |
| ||
— Filter canister and batteries after 30 days from date of purchase. |
|
| ||
| including the implied warranties of merchantability or fitness for a particular |
| ||
— Service trips to your home to teach you how to use the product. |
| purpose, are limited to one year or the shortest period allowed by law. |
| |
— Improper installation, delivery or maintenance. |
|
|
| |
|
|
| ||
— Failure of the product if it is abused, misused, altered, used commercially or used |
|
|
| |
|
|
| ||
for other than the intended purpose. | This warranty is extended to the original purchaser and any succeeding owner for | |||
— Use of this product where water is microbiologically unsafe or of unknown quality, | products purchased for home or office use within the USA. In Alaska, the warranty | |||
without adequate disinfection before or after the system. Systems certified for cyst | excludes the cost of shipping or service to your home or office. | |||
reduction may be used on disinfected water that may contain filterable cysts. | Some states do not allow the exclusion or limitation of incidental or consequential | |||
— Damage to the product caused by accident, fire, floods or acts of God. | ||||
damages. This warranty gives you specific legal rights, and you may also have other | ||||
— Incidental or consequential damage caused by possible defects with | ||||
rights, which vary from state to state. To know what your legal rights are, consult your | ||||
this appliance, its installation or repair. | ||||
local or state consumer affairs office or your state’s Attorney General. | ||||
• For how long after the original purchase? | ||||
Contact us at ge.com, or call | ||||
— One (1) year. | ||||
• How do I make a warranty claim? |
|
|
| |
— Return to the retailer from which it was purchased, along with a copy of the |
|
|
| |
“Proof of Purchase.” A new or reconditioned unit will be provided. This warranty |
|
|
| |