JVM2052DN
GE Spacemaker® Over-the-Range Microwave Oven
Dimensions and Installation Information (in inches)
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
Exhaust Connection: The hood exhaust has been designed to mate with a standard
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Optional Accessories (Available at additional cost)
Filler Panel Kits
JX52BL–Black
JX52WH–White
When replacing a 36" range hood, this kit fills in the additional width to provide a custom
between cabinets only; not for
Filter KitsJX81D–
Recirculating Charcoal
Filter Kit
To be used when the Spacemaker microwave oven cannot be vented to the outside.
Duct | Equivalent Feet |
A. | 5 ft. |
Transition Adaptor |
|
|
|
B. Wall Cap | 40 ft. |
|
|
C. 90° Elbow | 10 ft. |
|
|
D. 45° Elbow | 5 ft. |
|
|
E. 90° Elbow | 25 ft. |
|
|
F. 45° Elbow | 5 ft. |
|
|
G. Roof Cap | 24 ft. |
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.