TM
JVM3670BF/CF/SF/WF – GE Profile™ 36" Spacemaker® 1.8 Cu. Ft.
Optional Accessories (Available at additional cost)
Filter Kits
Charcoal Filter Kit
To be used when the Spacemaker microwave oven cannot be vented to the outside.
Specification Created 7/02
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs,or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of
ELBOWS, TRANSITIONS,WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct | Equivalent Feet | |
A. | 5 ft. | |
| Transition Adaptor |
|
B. Wall Cap | 40 ft. | |
|
|
|
C. | 90° Elbow | 10 ft. |
|
| |
D. 45° Elbow | 5 ft. | |
|
|
|
E. | 90° Elbow | 25 ft. |
|
|
|
F. | 45° Elbow | 5 ft. |
|
| |
G. Roof Cap | 24 ft. |
For answers to your Monogram,® GE Profile™ or |
|
|
GE appliance questions, visit our website at |
| Listed by |
GEAppliances.com or call |
| Underwriters |
GE Answer Center® service, 800.626.2000. | R | Laboratories |
|
|