D. REMOVING MAGNETRON

(Figures 11 Through 13)

(1)Remove vertgrille.

(2)Remove mount all.

(3)Remove outcase.

(4)Discinnect the wireleads.

(5)Remove the 3 screws and Magnetron very carefully.

NOTES:

When removing the magnetron, make sure that its dome does not hit any adjacent parts, or it may be damaged.

When replacing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition.

After replacing the magnetron, check for microwave energy leakage with a survey meter Check microwave energy leakage must be below the limit of 5 mW/cm2. (All service adjustments should be made for minimum microwave energy leakage readings.)

mount all

vertgrille

outcase

Figure 11

Magnetron

Figure 12

 

 

Figure 13

7-8

Page 19
Image 19
GE MV1526W, MV1526B service manual Removing Magnetron

MV1526W, MV1526B specifications

The GE MV1526B and MV1526W are advanced medium-voltage switchgear solutions designed for reliability, efficiency, and safety in various industrial and utility applications. These models from General Electric (GE) represent a significant leap forward in switchgear technology, incorporating state-of-the-art features and benefits for modern electrical systems.

One of the primary features of the MV1526B and MV1526W is their robust construction, designed to withstand the harshest environmental conditions. Built with high-quality materials, these models ensure long-lasting performance while providing superior protection against external elements such as moisture, dust, and extreme temperatures. This durability ensures low maintenance costs and extended service life, making them an excellent choice for long-term investments.

Both models utilize vacuum circuit breaker technology, which is critically important for medium-voltage applications. This technology minimizes arcing during operations, significantly enhancing safety and reducing maintenance periods. The vacuum interrupters are designed to provide superior fault interruption capabilities, ensuring that the electrical systems are safeguarded against overloads and short circuits.

The MV1526B and MV1526W also showcase GE's advanced digital controls and monitoring capabilities. Features such as real-time diagnostics and remote monitoring allow for proactive maintenance, enabling operators to identify potential issues before they escalate. This not only enhances system reliability, it also minimizes downtimes, ultimately resulting in greater operational efficiency.

Another significant characteristic of these models is their compact design. The MV1526B and MV1526W applications are engineered to maximize space while maintaining operational functionality. This compact footprint is particularly advantageous in environments where space is a premium, allowing for easier installations and future expansions.

Moreover, the flexibility of configuration is a standout feature of the MV1526 series. Users can customize their switchgear layout based on specific operational needs, accommodating various configurations for different applications. This adaptability makes the MV1526B and MV1526W suitable for a range of sectors, including energy, manufacturing, and commercial facilities.

In conclusion, the GE MV1526B and MV1526W models exemplify cutting-edge technology and engineering excellence, providing industrial and utility applications with versatile, reliable, and safe medium-voltage solutions. Their advanced features, including vacuum circuit breaker technology, digital monitoring capabilities, robust construction, and compact design, make them ideal choices for modern electrical infrastructure.