Conversion Instructions
GAS SUPPLY
• With the installation of this conversion kit, the cooktop |
should operate on LP gas at 10″ of water column |
pressure. |
• The pressure regulator must be connected in series |
with the manifold of the cooktop and must remain in |
series with the supply line. For proper operation, the |
maximum inlet pressure to the regulator must be no |
1CONVERT SURFACE BURNERS
AFirst remove, convert and replace the left side surface burners and then the right side surface burners.
Remove the grates, burner caps and burner heads. Remove the screws securing the burner bases
to the burners. Pull out the electrodes without removing the electrode leads.
more than 14″ water column pressure for LP gas. |
• When checking the regulator, the inlet pressure must |
be at least 1″ greater than the regulator output |
setting. If the regulator is set for 10″ of water column |
pressure, the inlet pressure must be at least 11.″ |
IMPORTANT – Disconnect the cooktop and the individual
Grate
Burner cap
Burner head
Electrode
Burner base screw (2)
Burner base
testing of the gas supply piping system at test pressures equal to or greater than 1/2 psig.
TURN OFF GAS AND
ELECTRIC SUPPLY
BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT THE
Electrical supply
BRemove the brass orifice spud in the chimney of each burner using a 9/32″ (7 mm) nutdriver.
CInstall the LP orifice spuds in their correct positions by number. Note: The LP orifices are shorter than the natural gas orifices.
84 | 71 |
L | L |
84 | 99 |
L | L |
Front
LP (Propane) Gas 10″ W.C.P.
Burner Output Rating in BTU/HR
Location | BTUs | Orifice Size |
LF, LR | 8,500 | 0.84 Lmm |
|
|
|
RR | 5,500 | 0.71 Lmm |
|
|
|
RF | 11,000 | 0.99 Lmm |
High Altitude Orifice Conversion Kit
Use for cooktop operation at elevations above 5000 ft. (1500m). Specify kit for Natural Gas or LP Gas when ordering:
Natural Gas High Altitude Orifice Conversion Kit | .........WB28X10114 |
LP High Altitude Orifice Conversion Kit | WB28X10115 |
2