Installation Instructions
PREPARING THE OPENING
1The following MINIMUM clearance dimensions must be maintained.
4CUTOUT DIMENSIONS OF THE COUNTERTOP
13″ MAX. Depth of uprotected overhead cabinets
30″ MIN. Clearance from countertop to unprotected overhead surface
15″ MIN. Height from countertop to nearest cabinet on either side of unit
To insure accuracy, it is best to make a template when cutting the opening in the counter.
behind the cooktop
from front edge
2″ MIN. Clearance from cutout to side wall on the left of the unit
If a 30″ clearance between the cooking surface and overhead combustible materials or metal cabinets cannot be maintained, a minimum clearance of 24″ is required and the underside of the cabinets above the cooktop must be protected with not less than 1/4″ insulating millboard covered with sheet metal not less than 0.0122″ thick.
2OVERALL COOKTOP DIMENSIONS
of cutout and front edge of countertop
JXTR32X CUTOUT FILLER TRIM KIT: A filler trim kit is available for use if your countertop cutout is larger than the dimensions shown, up to
5Make sure the wall coverings, countertop and cabinets around the cooktop can withstand heat (up to 200°F) generated by cooktop.
Cooktop
|
|
|
|
| |
|
| |
|
| at the conduit |
|
| location |
|
| |
28″ | ||
|
| on Model PP945 |
| ||
|
| & PP950 |
|
|
|
Wall covering, cabinets and countertop must withstand heat up to 200°F.
3 | Five inches (5″) |
|
| minimum vertical |
|
| clearance between |
|
| the cooktop bottom | 5″ Min. |
| and any combustible | Vertical Clearance |
|
| |
| surfaces. |
|
4