6POWER CORD AND CONDUIT INSTALLATION (CONT.)

8

4-WIRE INSTALLATION

Before–Power Cord and Conduit

 

C. For power cord installations only (see the next

Strain relief

 

step if using conduit), assemble the strain relief

Terminal

in the hole. Insert the power cord through the strain

block

relief and tighten. Allow enough slack to easily

 

attach the cord terminals to the terminal block.

 

If tabs are present at the end of the winged

 

strain relief, they can be removed for a better fit.

Bracket

NOTE: Do not install the power cord without a

 

strain relief. The strain relief bracket MUST be

Power cord

installed before reinstalling the rear range wiring

 

WARNING: The neutral wire of the supply

Terminal

circuit must be connected to the neutral terminal

block

located in the lower center of the terminal block.

 

The power leads must be connected to the lower

 

left and the lower right terminals of the terminal block.

The grounding lead must be connected to the frame

Ground

of the range with the ground plate and the green

strap

ground screw.

 

Ground strap

or

Neutral termi- nal

cover.

Squeeze connector

 

 

 

D. For conduit installations only, purchase a squeeze

 

Terminal

 

block

connector matching the diameter of your conduit and

 

 

 

assemble it in the hole. Insert the conduit through the

 

 

squeeze connector and tighten. Allow enough slack to eas-

 

ily attach the wires to the terminal block.

 

Bracket

NOTE: Do not install the conduit without a squeeze con-

 

 

 

nector. The squeeze connector MUST be installed before reinstalling the rear range wiring cover.

73-WIRE INSTALLATION

WARNING: The neutral or ground wire of the power cord must be connected

to the neutral terminal located in the center of the terminal block. Ground strap must connect

the neutral teminal to the ground plate. The power leads must be connected to the lower

left and the lower right terminals of the terminal block.

Terminal block

Power Cord

DO NOT remove the ground strap connection.

(appearance

 

 

 

FOR POWER CORD INSTALLATION

may vary)

 

A. Remove the 3 lower terminal screws from the terminal block. Neutral

 

B. Insert the 3 terminal screws through each power cord termi-

terminal

 

 

 

nal ring and into the lower terminals of the terminal block. Be

Ground

 

certain that the center wire (white/neutral)

strap

 

 

 

is connected to the center lower position of the terminal

Ground

 

block.

 

plate

 

C. Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

Power cord

A. Loosen the 3 lower terminal screws from the terminal block.

B. Strip wire to expose tip about 5/8" long. Insert the center

(white/neutral) wire tip through the bottom center terminal block opening. On Conduit

certain models, the wire will need to be inserted

Terminal

through the ground strap opening and then into the bottom

 

block

center block opening. Insert the two side bare wire tips into

 

 

 

the lower left and the lower right terminal block openings.

 

 

 

Wire tips

 

 

 

C. Tighten screws until the wire is firmly secured (35 to 50 inch-lbs.).

 

 

 

 

 

 

Do not over-tighten the screws.

 

 

 

NOTE: ALUMINUM WIRING: Aluminum building wire may

 

 

 

be used but it must be rated for the correct amperage and voltage.

 

 

 

PROCEED TO STEP 9.

 

 

 

 

 

Conduit

 

 

 

 

FOR POWER CORD INSTALLATION

After–Power Cord

 

A. Remove the 3 lower terminal screws from

 

 

 

the terminal block. Remove the ground screw

 

 

and ground plate and retain them. Cut and discard

 

Neutral

the ground strap. DONOTDISCARDANYSCREWS.

 

 

terminal

B. Insert the one ground screw into the power cord ground

Terminal

 

wire terminal ring, through the ground plate and into

block

 

 

Ground plate

the frame of the range.

 

 

(grounding to

 

 

C. Insert the 3 terminal screws (removed earlier) through

 

range)

each power cord terminal ring and into the lower terminals

 

 

of the terminal block. Be certain that the center wire

Ground

 

(white/neutral) is connected to the center lower position

 

screw

 

of the terminal block. Tighten screws securely into

 

 

 

the terminal block.

 

 

FOR CONDUIT INSTALLATION

After–Conduit

A.Loosen the 3 lower terminal screws from the terminal block.

Remove the ground screw and ground plate and retain

Terminal

Ground

them. Cut and discard the ground strap. DO NOT

plate

block

DISCARD ANY SCREWS.

(grounding

 

B. Strip the wire to expose tip about 5/8" long. Insert

 

to range)

 

 

the ground bare wire tip between the range frame

Wire

 

and the ground plate (removed earlier) and secure

tips

 

 

 

it in place with the ground screw (removed earlier).

 

 

Insert the bare wire (white/neutral) tip through the bottom

 

center of the terminal block opening. Insert the two

Ground screw

 

side bare wire tips into the lower left and the lower

 

 

 

right terminal block openings.

 

 

C. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated for the correct amperage and voltage.

9 REPLACE THE WIRE COVER

Replace wire cover on range back by sliding its left edge under

the retaining tabs and replace the screws removed earlier. Make sure that no wires are pinched between cover and range back.

Wire cover

Page 3
Image 3
GE 31-10673 09-08 JR, PS968SPSS Wire Installation, Replace the Wire Cover, Power Cord and Conduit Installation