Specification Created 11/08 240445
Listed by
Underwriters
Laboratories
PSB120 0NBB /WW GE Profile Advantium® 120 Volt - 30" Wall Oven
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
cooking_tower_solid_floor.epsCL(Must support 130 lbs.)2 x 4’s orequivalentsolid floorSuitablebracingto supportrunners21-5/8"over centerlineof cabinet
Cabinet Width
(inches)
W Width
H HeightDDepth(excluding
handle)
X Cutout Width
Y Cutout HeightZ Cutout Depth(minimum)
PSB1200/1 without
accessory drawer 30 29-25/32 19 -1/8 21-3/4 25-1/8 17-1/ 2 23-1/2
PSB1200/1 with
accessory drawer 30 29-25/32 22-1 /4 21-3/4 25-1/8 to
28-1/ 2* 21 23-1/ 2
*For existing cutouts a maximum width of 28-1/2" is acceptable
Note: 2" minimum
between cutouts when
installed above warming
drawer or single wall oven.
Installation Information:
Before installing, consult
installation instructions
packed with product for
current dimensional data.
Note: PSB1200/1 series
Advantium can be
installed below GE/GE
Profile non-downdraft
gas and electric cooktops.
It CANNOT be installed
below induction or Monogram
(2GU3841385) gas cooktops.
Note: PSB1200/1 series Advantium
oven comes with two lower trim pieces.
One is for use above 36-inch height
installations and one is for use b elow 36-
inch installations. Use of the accessory
drawer will replace the bottom trim piece
for applicable installations. Please see
installation instructions for full details.
Advantium wall oven/GE Profile cooking tower dimensions and cabinet ins tallation information (in inches)
adv_240_120_cooktower_dia.eps
1" Min. above toekick or adjust
to oven installation height
2" MIN between cutouts
2-1/2" MIN between cutouts
recommended—2" MIN required
9-1/4" cutout height
28-1/2" cutout width
Junction box location
AB
ABConstruct Solid Bottom
MIN 3/8" Plywood Supported by
2 x 4 or 1 x 2 Runners, all Four Sides.
(Must Support 150 lbs. for Advantium)
(Must Support 200 lbs. for Wall Oven)
4-3/16
D
Excluding
Handle
H
W
Conduit
(46" long)
Cabinet width
(240-volt models only)
4-3/16"
23-1/2"
Cutout depth
Junction
box location
17-1/2"
Cutout height
29-25/32"
19-1/32"
21-1/2"
Excluding
Handle
Conduit
(48-1/2"
long)
B
30"
5" min.from
floor 1" min.
above toekick
A= Allow 1" overlap of oven over bottom edge of cutout, and allow 1-1/4" overlap at top edge of cutout.B= Allow 11/16"-3/4" for overlap of oven over side edges of cutout.Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
A
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
4-3/16"
23-1/2"
Cutout depth
Junction
box location
17-1/2"
Cutout height
29-25/32"
19-1/32"
21-1/2"
Excluding
Handle
Conduit
(48-1/2"
long)
B
30"
5" min.from
floor 1" min.
above toekick
A= Allow 1" overlap of oven over bottom edge of cutout, and allow 1-1/4" overlap at top edge of cutout.B= Allow 11/16"-3/4" for overlap of oven over side edges of cutout.Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
A
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.