GE PVB98SN GE Profile 36 Telescopic Downdraft System, Venting Duct Information, Plan the Ductwork

Models: PVB98SNSS PVB98SN

1 3
Download 3 pages 39.18 Kb
Page 2
Image 2
Venting Duct Information

PVB98SN

GE Profile36" Telescopic Downdraft System

Venting Duct Information

Duct Pieces

Equivalent Length*

Duct Pieces

Equivalent Length*

6" Round

1 ft. (per foot length)

3-1/4" x 10"

5 ft.

to 6" Round

Straight

 

Transition

 

3-1/4" x 10"

 

6" Round

20 ft.

1 ft. (per foot length)

to 3-1/4 x 10"

Straight

 

Transitions

 

 

 

90° Elbow

 

6"

 

3-1/4" x 10"

12 ft.

15 ft.

to 6" Round

°

Transition

 

90 Elbow

 

90° Elbow

 

 

 

 

6"

9 ft.

6" Round

21 ft.

45° Elbow

 

Wall Cap

 

 

with Damper

 

3-1/4" x 10"

16 ft.

3-1/4" x 10"

27 ft.

Wall Cap

90° Elbow

 

with Damper

 

3-1/4" x 10"

5 ft.

6" Round

20 ft.

Roof Cap

45° Elbow

 

 

 

3-1/4" x 10"

24 ft.

6" Round

24 ft.

45° Elbow

 

Roof Vent

 

6" Round

 

SHOULD NOT EXCEED 100 EQUIVALENT FT.

to 3-1/4 x 10"

7 ft.

*Equivalent length of duct pieces are based on actual test conducted

by GE Evaluation Engineering and reflect requirements for good

Transitions

 

 

venting performance with a downdraft rated at 500 CFM

 

 

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

Plan the Ductwork

1. This downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Two different discharge directions are available with side-to-side adjustment for the accurate alignment of ductwork.

2. For best performance: choose the ducting option which allows

the shortest length of ductwork and a minimum number of elbows and transitions. Check location of floor joists, wall joists, wall studs, electrical wiring or plumbing for possible interference.

Right discharge

Left discharge (as shipped)

Steps to Determine Flexible Ducting’s Equivalent Length

1. Measure the actual amount of offset (Maximum 3" recom- mended). The effect upon airflow is dependent upon the amount of offset.

2. Calculate the equivalent ducting allowances using: (__in. offset) x (14 Ft. per inch)

=__Ft. equivalent length.

1. Ensure that the total equivalent length of ducting does not exceed the maximum recommendation of 150 feet.

Listed by

Underwriters

Laboratories

Specification Created 9/08

220967

Page 2
Image 2
GE PVB98SNSS dimensions GE Profile 36 Telescopic Downdraft System, Venting Duct Information, Plan the Ductwork