Planning Information

Planning Information

PRODUCT DIMENSIONS

AND CLEARANCES

32"

Case

Depth

72"

36"

34"

Including

Handles

This Monogram free-standing refrigerator requires the following clearances for proper air circulation, plumbing and electrical connections.

Air Circulation Clearances:

1/8" on each side

1" at the top

1" at the back

Installation in a corner:

Allow 4" clearance on each side to an adjacent wall for a 90° opening and access to drawers.

THE INSTALLATION SPACE

The opening width must be 36-1/4".

36-1/2"

Wall View

Electrical

Area

73" min.

Water Supply

Water And Electrical Locations

The opening must be prepared with the electrical and water supply located as shown.

Additional Specifications

A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall.

NOTE: GFI (ground fault interrupter) is not recommended.

• Water line can enter the opening through the

floor or through an adjacent cabinet, as close to

the back wall as possible. The water line should be

1/4" O.D. copper tubing between the cold water

line and water connection location at the rear of

14-1/4"

160° Door Swing

PRODUCT DIMENSIONS19"Air Circulation Clearances:

the refrigerator. Installation of an easily accessible

shut off valve in the water line is recommended.

90° Door Swing

28"

22"

On the freezer side, allow 14-1/4" min. clearance for removal of ice bin.

On the fresh food side, allow 19" min. clearance to wall for removal of drawers.

3