58 Refrigerator Dead - No Sound, No Cooling
Are the interior lights on? Check house supply voltage.
Are 120 VAC present?
NO House wiring
problem.
NO
Check for 120 VAC at 3-pin
connector at the rear of the
unit.
Are 120 VAC present?
YES
Repair wiring
connections at
3-pin connector.
YES
Unplug J2
connector from
main control
board.
Check for 12 VDC
at control board
pins J2-3 to J2-8.
Voltage present?
YES
Short in fan motor circuit.
Go to Evaporator Fan Not
Running flowchart or
Condenser Fan Not Running
flowchart.
YES
Unplug J4 connector from
main control board.
Check for 12 VDC at
control board pins J4-2 to
J4-3.
Voltage present?
NO
Unplug the temperature
control harness.
Does the refrigerator
start once the harness is
unplugged?
YES
Replace temperature
control board.
YES
Replace main
control board.
NO
Verify thermistors are
within proper range
using the thermistor
values chart.
Is the resistance
within range?
NO
Replace main
control board.
YES
Check wiring
connections. If wiring
is OK, replace
thermistor.
YES
Repair or replace
power cord.
NO