KW Rating |
|
240V | 6.8 |
|
|
208V | 5.1 |
Breaker Size |
|
240V | 40 Amps |
|
|
208V | 30 Amps |
These ovens may be installed in combination with a Monogram warming drawer.
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating.
Installation Information: Before installing, consult installation instructions packed with product for current dimensional data.
51"
10" |
Locate Electrical Outlet Within 10"
of Left Side of Opening and 44" Above Cutout Floor or 5" Below Cutout Floor
| ||
Min. | 25" Min. | |
Max. | ||
51" | ||
|
27"
The solid bottom or runners must be level with the bottom of the cutout, or the bottom trim may not install correctly and could interfere with the door opening. If the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. The runners and braces must support 300 lbs. (135 kg).
Depth
For answers to your Monogram appliance questions, visit our website at monogram.com or call GE Answer Center® service, 800.626.2000.
Per Warming
Drawer
Requirement
Against Rear
Wall Per
Warming
Drawer
Requirement
2 (5.1 cm)
Min.
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
1 (2.5 cm) Min. Above Toekick
Listed by Underwriters Laboratories
Specification Revised 5/07 | 130187 |