Monogram.™
ZGG36N30YSS–36” Outdoor Cooking Center
Dimensions and Specifications (in inches)
3" Min. for Lid Clearance
3" Min. for Lid | |
Clearance |
|
4x4 Opening for Gas Supply Line
Opening for Access Doors
4x4 Opening for Gas Supply Line
Opening for Access Doors
Installation in a combustible enclosure.
ZX36JYSS insulated jacket is required.
•Combustible enclosures require insulated jackets.
ZX36JYSS for 36” models and ZX48JYSS for 48” models. The insulated jacket must be supported from the bottom by a solid deck or ledge on each side beneath the jacket.
•Construct the enclosure as shown and place the insulated jacket into the enclosure. Place the cooking center into the jacket. No installation hardware is required.
Created 7/97
Installation in a non-combustible enclosure.
•In a
Clearances - All Models
•Allow 3” at the rear for lid clearance.
•Allow at least 12” clearance at the back of the grill when exhaust is directed to a window or a surface that is difficult to clean.
•Allow at least 6” clearance on each side to any
•Allow at least 12” clearance on each side to combustible vertical materials.