Monogram.™
ZISS360NMSS - GE Monogram 36"
THE INSTALLATION SPACE | 36" Models 12" | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| 7" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
84 1/2" max | Electrical |
|
|
|
|
|
|
|
|
|
|
| |||||
Area | 5" |
|
|
|
| ||||||||||||
83 1/2" min |
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Finished |
|
|
|
|
|
|
|
|
|
|
|
| 74" From Floor | ||||
Opening |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
| 24" |
|
|
|
|
|
|
|
|
|
| to Bottom | |||
|
|
|
|
|
|
|
|
|
|
|
|
| of Electrical | ||||
|
|
| 5" |
| Water Supply | 5" |
|
|
| ||||||||
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 1/2" |
| ||
|
|
| 3 1/2" |
|
|
|
|
|
|
|
|
|
|
|
|
35"
Case Width
| *84" From | |||
Floor to | ||||
Top Frame | ||||
at | ||||
Rear |
|
|
| |
|
|
|
|
36"
Frame to Frame
*Shipping height. The refrigerator can be adjusted to fit into a cutout that is
Water And Electrical Locations
The opening must be prepared with the electrical and water supply located as shown.
The cutout depth must be 24".
Designed for industry standard flush installation. The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.
The cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed the 24” installation depth shown. The top case trim overlaps the bottom of the soffit.
Frameless cabinets:
The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips.
Additional Specifications
•A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded
Note: GFI (ground fault interrupter) is not recommended.
•Water line can enter the opening through the floor or back wall. The water line should be 1/4" O.D. copper tubing between the cold water line and
water connection location, long enough to extend
to the front of the refrigerator. Installation of an easily accessible shut off valve in the water line is recommended.
Product Clearances
These refrigerators are equipped with a 2 position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls
is restricted.
13"15"
Allow minimum clearances for freezer door and fresh food door for a full 130° door swing and to allow for pan removal.
4" minimum clearance is required when door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.
For answers to your Monogram,® GE Profile™ or GE appliance questions, visit our website at GEAppliances.com or call
GE Answer Center® service, 800.626.2000.
Specification Revised 2/02
Listed by
Underwriters
RLaboratories
As an ENERGY STAR® Partner,
GE has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.