IR CHANNEL CONFIGURATION
Setting The IR Channel
Use the following procedure to set the proper IR channel on the 2x2 Switcher for HDMI 1.3.
1Press and hold the EDID button.
2While holding the EDID button, press and release the Reset button. The input LED indicators, on the front panel, will represent the current IR channel for the Switcher: A blinking LED corresponds to DIP switch set to the ON position. An inactive LED corresponds to a DIP switch set to the OFF position.
In the illustration above, the LED for Input 1 is blinking and the LED for Input 2 is inactive. This indicates that the Switcher is set to IR channel 1.
IMPORTANT: The selected IR channel must be the same as the IR channel set on the IR Remote Control Unit (see page 9). Refer to the table below for setting the IR channel.
IR Channel Table
Input LED 1 | Input LED 2 | IR Channel |
OFF | OFF | 0 |
OFF | ON | 1 |
ON | OFF | 2 |
ON | ON | 3 |
3Continue holding the EDID button while pressing and releasing the Reset button to cycle to the next IR channel.
4Once the proper IR channel has been selected, release the EDID button.
10