8040A and 8050A Operating Manual

system specifications

 

8040A

8050A

 

 

 

Lower cut-off frequency, -3 dB

45 Hz

35 Hz

Upper cut-off frequency, -3 dB

21 kHz

21 kHz

Free field frequency response of

48 Hz - 20 kHz

38 Hz - 20 kHz

system (± 2.0 dB)

 

 

 

 

 

Maximum short term sine wave

 

 

acoustic output on axis in half

 

 

space, averaged from 100 Hz to

 

 

3 kHz

105 dB SPL

110 dB SPL

@ 1 m

@ 0.5 m

111 dB SPL

116 dB SPL

Maximum long term RMS acoustic

99 dB SPL

101 dB SPL

output in same conditions with IEC

 

 

weighted noise (limited by driver

 

 

unit protection circuit) @ 1 m

 

 

 

 

 

Maximum peak acoustic output

115 dB SPL

120 dB SPL

per pair above console top, @ 1

 

 

m from the engineer with music

 

 

material

 

 

 

 

 

Self generated noise level in free

10 dB

10 dB

field @ 1m on axis (A-weighted)

 

 

 

 

 

Harmonic distortion at 90 dB SPL

 

 

@ 1m on axis

 

 

Freq. 50 to 100 Hz

< 2 %

< 2 %

> 100 Hz

< 0.5 %

< 0.5 %

 

 

 

Drivers:

 

 

Bass

165 mm (6 1/2")

205 mm (8")

Treble

19 mm (3/4")

25 mm (1")

Both drivers are

metal dome

metal dome

magnetically shielded

 

 

 

 

 

Weight:

8.6 kg (18.9 lbs)

12.7 kg (28 lbs)

 

 

 

Dimensions:

 

 

Height (without table support

350 mm (13 13/16“)

433 mm (17 1/16")

Height (including table support)

365 mm (14 3/8“)

452 mm (17 13/16")

Width

237 mm (9 3/8“)

286 mm (11 1/4")

Depth

223 mm (8 13/16“)

278 mm (10 15/16")

 

 

 

crossover Section

 

8040A

8050A

 

 

 

Input connector XLR female

Pin 1 gnd, pin 2 +, pin 3 -

 

 

 

Input impedance

10 kOhm balanced

 

 

 

 

Input level for maximum short term

Adjustable from +6 to -6 dBu

output of 100 dB SPL @ 1m:

 

 

 

 

 

Crossover frequency, Bass/Treble

3.0 kHz

1.8 kHz

 

 

 

Treble tilt control operating range in

From +2 to -4 dB &

From +2 to -4 dB &

2 dB steps

MUTE @ 15 kHz

MUTE @ 15 kHz

 

 

 

Desktop low frequency control

-4 dB @ 160 Hz

-4 dB @ 160 Hz

operating range

 

 

 

 

 

Bass roll-off control operating

From 0 to -6 dB

From 0 to -6 dB

range in 2 dB steps

@ 45 Hz

@ 35 Hz

 

 

 

Bass tilt control operating range in

From 0 to -6 dB @

From 0 to -6 dB @

2 dB steps

100 Hz & MUTE

100 Hz & MUTE

 

 

 

 

The 'CAL' position is with all tone controls

 

set to 'off' and the input sensitivity control

 

to maximum (fully clockwise)

 

 

 

Amplifier Section

 

8040A

8050A

 

 

 

Bass amplifier short

90 W (8 Ohm load)

150 W (6 Ohm load)

term output power

 

 

Treble amplifier short

90 W (8 Ohm load)

120 W (8 Ohm load)

term output power

 

 

Long term output power is limited

 

 

by driver unit protection circuitry

 

 

 

 

 

Amplifier system distortion

 

 

at nominal output

0.05 %

0.05 %

THD

SMPTE-IM

0.05 %

0.05 %

CCIF-IM

0.05 %

0.05 %

DIM 100

0.05 %

0.05 %

Signal to Noise ratio, referred to

 

 

full output

100 dB

100 dB

Bass

Treble

100 dB

100 dB

 

 

 

Mains voltage

100, 120, 220 or 230 V

 

according to region

 

 

 

 

Voltage operating range

±10 %

±10 %

 

 

 

Power consumption

 

 

Idle

10 VA

10 VA

Full output

110 VA

170 VA

 

 

 

Genelec Document D0003R001a Copyright Genelec Oy 2.2005-. All data subject to change without prior notice

www.genelec.com

 

 

International enquiries: Genelec, Olvitie 5 FIN-74100, Iisalmi, Finland Phone +358 17 83881 Fax +358 17 812 267 Email genelec@genelec.com

In the U.S. please contact: Genelec, Inc., 7 Tech Circle Natick, MA 01760, USA Phone +1 508 652 0900 Fax +1 508 652 0909

Email genelec.usa@genelec.com

In China please contact: Beijing Genelec Audio Co. Ltd. Jianwai SOHO, Tower 12, Room 2306 39 East 3rd Ring Road

Chaoyang District, Beijing 100022, China Phone +86 0 5869 7915

Fax +86 10 5869 7914

In Sweden please contact: Genelec Sverige

Box 5521, S-141 05 Huddinge Phone +46 8 449 5220

Fax +46 8 708 7071 Email info@genelec.com