Generac NP-50LPG Recreational Vehicle Generator

GENERATOR CONTROL PANEL

Mounted on the generator control panel (Figure 2) are the fol- lowing features:

Figure 2 — Generator Control Panel

FUEL PRIMER

Before starting a cold engine (if it has not been started in more than two weeks), you must press this switch to bring fuel from the tank to the fuel regulator. This rocker type switch springs back into its original position when you release it.

START/STOP SWITCH

To crank and start the engine, hold this switch at its START position. Release the switch when the engine starts. To stop an operating engine, press and hold the switch in its STOP position until the engine shuts off. The switch center position is the RUN position.

FUSE

Protects the engine DC control circuit against electrical over- load. If the fuse element has melted open due to overloading, the engine cannot be cranked. If you must replace it, use only an identical replacement fuse.

MAIN BREAKER

Protects generators AC output circuit against overload and pro- vides a method of turning OFF the generators 120/240 volts AC output to vehicle circuits. The NP-50LPG has one 20 amp breaker and one 30 amp breaker.

NOTE: If the Series NP-50LPG has been reconnected for dual voltage AC output (120/240 volts), you can install line break- ers having an amperage rating that is different than stated above. The replacement line breakers consist of two sepa- rate breakers with a connecting piece between the breaker handles (so that both breakers will operate at the same time). If the unit is reconnected for dual voltage, IT IS NO LONGER

RVIA LISTED.

OPTIONAL REMOTE

START/STOP PANEL

A remote mounted Start/Stop Panel is available, which allows you to start and stop the generator engine conveniently from inside the vehicle.

Figure 3 — Optional Remote Panel (Model 9042)

R e c r e a t i o n a l V e h i c l e G e n e r a t o r

7