GENERATOR CONTROL PANEL
Mounted on the generator control panel (Figure 2) are the fol- lowing features:
Figure 2 — Generator Control Panel |
FUEL PRIMER
Before starting a cold engine (if it has not been started in more than two weeks), you must press this switch to bring fuel from the tank to the fuel regulator. This rocker type switch springs back into its original position when you release it.
START/STOP SWITCH
To crank and start the engine, hold this switch at its START position. Release the switch when the engine starts. To stop an operating engine, press and hold the switch in its STOP position until the engine shuts off. The switch center position is the RUN position.
FUSE
Protects the engine DC control circuit against electrical over- load. If the fuse element has melted open due to overloading, the engine cannot be cranked. If you must replace it, use only an identical replacement fuse.
MAIN BREAKER
Protects generators AC output circuit against overload and pro- vides a method of turning OFF the generators 120/240 volts AC output to vehicle circuits. The
NOTE: If the Series
RVIA LISTED.
OPTIONAL REMOTE
START/STOP PANEL
A remote mounted Start/Stop Panel is available, which allows you to start and stop the generator engine conveniently from inside the vehicle.
Figure 3 — Optional Remote Panel (Model 9042)