STEP 2: USING YOUR TRANSFER SWITCH:
NEVER run portable generators indoors or in garages, basements, or sheds. Portable generators should always be used at least 5 feet away from windows, doors, vents, or any other opening. Carbon Monoxide (CO) from a generator is deadly and can kill you in minutes. Read and follow all generator directions before use.
Transferring from Utility Power to Generator Power:
1.Move generator outdoors. Be sure your generator is located at least 5 feet from windows, doors or other openings to prevent dangerous carbon monoxide fumes from entering your home.
2.Insert the male plug of the Power Cord into the correct outlet on the generator.
3.Plug in the female connector of the Power Cord to the inlet (if provided) located on the bottom of the Transfer switch.
4.Turn OFF all circuit breakers in the Transfer switch and Main load center.
5.Start the generator outdoors, following the procedures described in the generator’s Owner’s Manual furnished by the manufacturer.
6.Turn ON the GENERATOR MAIN circuit breaker in the Transfer switch.
7.Turn ON individual circuit breakers in the Transfer switch and the Main Load Center up to the continuous wattage rating of your generator. If the Generator
Main breaker trips, you have overloaded the generator. Some circuit breakers must be turned OFF to avoid damage to the generator or loads being connected.
Transferring from Generator Power to Utility Power:
1.On the Transfer switch, turn OFF Generator MAIN breaker and turn ON Utility MAIN breaker. To do this, slide the interlock mechanism up with the left hand while turning ON the 200 amp circuit breaker.
2.Turn ON any branch circuit breakers in the Transfer switch and Main Load Center that are OFF.
3.Shut down the generator, following the procedures in the generator Owner’s Manual.
4.Unplug the power cord from the Transfer switch and then the generator.
5.Let the generator cool down before storing in a dry, secured location.
6.To ensure that your generator will work properly when you need it, it is important to start and run your generator under load regularly and keep the tank filled with fresh fuel. Perform the above steps at least ONCE A MONTH to keep the generator properly “exercised.”
| Protected by US Patent No. US 6,861,596 B2 |
| Generac Power Systems, Inc. |
| Toll Free: |
| www.generac.com |
| 0196970SBY |
© 2012 Generac Power Systems, Inc. All Rights Reserved. GenTran and Generac are registered trademarks of Generac Power Systems, Inc. | PN 50925 Rev A |
3