Generac 6500XL Operating The Generator, Starting the Engine, Connecting Electrical Loads, Idle

Models: 6500XL

1 20
Download 20 pages 27.63 Kb
Page 7
Image 7
OPERATING THE

OPERATING THE

GENERATOR

_ CAUTION!loadsNeverelectrical connectedstartANDor stopwith unitthe withconnected devices turned ON.

Starting the Engine

Disconnect all electrical loads from the generator. Follow these start instructionsteps in numerical order:

I.Turn the fuel valveto the "On" position (Figure 4).

2.Make sure the Idle Control switch is in "Off' position (Figure 5).

IDLE

3. Set the Run/Stop switch to "Run" position (Figure 6).

4.Placethe choke lever in the "Full" choke position (Figure7).

5.Grasp the recoil handle and pull slowly until slight resistance is felt.Then pull rapidly one time only to start engine.

If engine starts,proceed to step 7.

Ifengine fails to start, proceed to step 6.

6.Move the choke lever to "Half" choke position, and pull recoil handle twice.

If engine fails to start, repeat steps 4 thru 6.

7.Move choke lever to "Run" position. If engine falters, move choke lever to "Half" choke position until the engine runs smoothly and then to "Run" position.

NOTE: If engine still fails to start after 3 pulls,check for proper oil level in crankcase.This unit is equipped with a Low Oil Shutdown System.Seeengine manual.

Refer to the engine owner's manual for complete

starting instructions.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 VottAC, single phase,60 Hz electrical loads.

Do Not connect 240Volt loads to the 120Volt receptacles.

Do Not connect 3-phase loads to the generator.

Do Not connect 50 Hz loads to the generator.

DO NOT OVERLOADTHE GENERATOR. See "Don't Overload the Generator" on page I I.

Page 7
Image 7
Generac 6500XL owner manual Operating The Generator, Starting the Engine, Connecting Electrical Loads, Idle