Generac Portable Products SVP5000 Generator

TROUBLESHOOTING

Problem

Cause

Solution

 

1.

Circuit breaker is open.

1.

Reset circuit breaker.

Engine is running, but

2.

Poor connection or defective cord

2.

Check and repair.

 

set.

 

 

no AC output is

 

 

 

3.

Connected device is bad.

3.

Connect another device that is in good

available.

 

 

 

condition.

 

 

 

 

 

4.

Fault in generator.

4.

Contact Generac service facility.

 

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

Engine runs good but

2.

Generator is overloaded.

2.

See “Don’t Overload the Generator” on

 

 

 

page 9.

bogs down when loads

 

 

 

3.

Engine speed is too slow.

3.

Contact Briggs & Stratton service

are connected.

 

 

 

facility.

 

 

 

 

 

4.

Shorted generator circuit.

4.

Contact Generac service facility.

 

1.

On/Off switch set to Off (o).

1.

Set switch to On (–).

 

2.

Dirty air cleaner.

2.

Clean or replace air cleaner.

 

3.

Out of gasoline.

3.

Fill fuel tank.

 

4.

Stale gasoline.

4.

Drain gas tank and fill with fresh fuel.

 

5.

Spark plug wire not connected to

5.

Connect wire to spark plug.

 

 

spark plug.

 

 

Engine will not start; or

6.

Bad spark plug.

6.

Replace spark plug.

7.

Water in gasoline.

7.

Drain gas tank; fill with fresh fuel.

starts and runs rough.

8.

Overchoking.

8.

Put choke lever to “Run” position.

 

9.

Low oil level.

9.

Fill crankcase to proper level.

 

10.

Excessively rich fuel mixture.

10.

Contact Briggs & Stratton service

 

 

 

 

facility.

 

11.

Intake valve stuck open or closed.

11.

Contact Briggs & Stratton service

 

 

 

 

facility.

 

12.

Engine has lost compression.

12.

Contact Briggs & Stratton service

 

 

 

 

facility.

Engine shuts down

1.

Out of gasoline.

1.

Fill fuel tank.

2.

Low oil level.

2.

Fill crankcase to proper level.

during operation.

3.

Fault in engine.

3.

Contact Briggs & Stratton service

 

 

 

 

facility.

 

1.

Load is too high.

1.

See “Don’t Overload the Generator” on

Engine lacks power.

 

 

 

page 9.

2.

Dirty air filter.

2.

Replace air filter.

 

3.

Engine needs to be serviced.

3.

Contact Briggs & Stratton service

 

 

 

 

facility.

Engine “hunts” or

1.

Choke is opened too soon.

1.

Move choke to halfway position until

 

 

 

engine runs smoothly.

falters.

2.

Carburetor is running too rich or

2.

Contact Briggs & Stratton service

 

 

too lean.

 