BTS Touch Sensitive Switch

Installation Instruction

Specifications

Specifications

Setting JP

 

SPDT relay rating: 3A@ 125V~

1

 

2

 

 

Current: 60mA~100mA@12V DC

3

 

4

 

 

Power input :12~24 V DC

5

 

 

 

 

BTS-486

1 30

Relay output

Relay output

Com.

 

N. C. (Touched)

Com.

 

N. O.

 

 

Relay output

Relay output

Com.

 

N. O. (Touched)

Com.

 

N. C.

 

 

Operating Temper.: - 20~+70ºC JP setting:

JP1: Relay output model

JP2: LED lighting or blinking setting

Jp3~5: LED brightness setting

Relay

(Light is lighting)

(Light is blinking.)

(Green) (Touched)

(Red)

BTS-300 , 400-ANSI

(Red)

(Green)

(Touched)

Relay contact output (free voltage contact)

12~24VDC power input

Relay

(Green) (Touched)

(Green)

Relay output model

control and LED

brightness setting

Setting JP

Timer delay (Seconds)

1 30

(Touched)

(Red) (Touched)

(Touched)

(Red)

Connecting Diagram

BTS-200 adds an extra

Control Device(Outdoor)

Fig. A

 

 

 

trigger for remote control

 

N.C.

 

purpose; it has the same

 

 

Relay output

Com.

 

effect as touching motion.

control

N.O.

 

 

 

 

 

T h e d i a g r a m s b e l o w i l l u s t r a t e t h e t w o

 

 

 

 

recommended ways of installing the BTS Touch

(Trigger)

 

TR

 

Sensitive Switch and access control devices after

 

TR

 

 

 

 

power input (power on).

 

 

N.C.

Locking Device

 

 

 

 

 

 

Com.

(fail-safe)

 

Power Supply

 

 

 

Shorten N.O.

 

In Fig. A, BTS directly controls the release of fail-

 

 

 

 

 

 

safe(Power to Lock) locking device.

 

 

 

 

 

 

BTS Touch Sensitive Switch

 

 

 

(Indoor)

 

 

BTS-200 adds an extra

Control Device(Outdoor)

Fig. B

 

 

 

trigger for remote control

 

N.C.

 

purpose; it has the same

 

 

Relay output

Com.

 

effect as touching motion.

control

N.O.

 

 

 

 

 

In Fig. B, For fail-secure(Power to Unlock) locking

(Trigger)

 

TR

 

devices the contact on control device should be sat

 

TR

 

 

 

 

to N.O. The relay time of BTS is the same as the

 

 

N.C.

Locking Device

release time of locking device in both cases.

 

 

 

 

Com.

(fail-secure)

 

 

 

 

Power Supply

 

 

 

Shorten N.O.

 

 

 

 

 

 

BTS Touch Sensitive Switch

 

 

 

(Indoor)

 

 

IMPORTANT NOTICE:

1.It is important to take extra notice on the maximum voltage and current output that the rated of relay contact to be used.

2.Make sure that the "+" and "-" wire are connected correctly.

Copyright © 2008 GIANNI INDUSTRIES, INC. All rights reserved.

P-MU-BTS200 Ver. L Published on 2008.06.09

Page 1
Image 1