The Digital Keyless Entry System (5 digit)
Operation User's Manual
|
|
(Surface Mount) | (Mount) |
DG-12
(Mount/ANSI size)
ANSI Box
I.Features:
5 digit codes
Door Reed Switch Input for
10 user PINs
Fully Programmable via keypad and master code
Invalid PIN
II. Specifications:
Operating Voltage:9~14 Vdc
Current Draw: Average 30mA, Peak 80mA @ 12Vdc
Input: One
Relays: N.O./N.C./Com. Output (free voltage contact), 3A@ 125Vac or 30Vdc
Case Material: ABS (UL94V0)
Operating
Ambient Humidity:0~95% relative humidity
Visual Signals:
Green: Power on
Red: Relay activated
Yellow: Program
Factory Master Code: 12345
Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly password attempted.
Relay Activation Time: (*20)
Pulse mode:1~99 seconds(01~99)
Latching mode(00)
EPROM:
User PINs: (*01~*10)It is possible to program 10 different user PIN codes.
Copyright Gianni Industries, Inc. All Rights Reserved. |
|
Page: 1/ 2 |