III. Program Instruction:

III. Program Instruction:

‹Enter Program Mode:

1.Enter the master code twice (Factory master is 1234)

→2 beeps and the Yellow LED will light up.

you are now in the "programming mode".

2.Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.

‹Exiting from the program mode:

1.Press#to exit from the programming mode.

2.Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.

‹To Enter a User CodeEnter the Programming mode

1.Enter the slot position code 「*01~10→????user code 4 digitbeep→enrolled→ Press # to exit from the programming mode, or program other operating.

2.Note: The codes"0000","1234" or master code are not be used for PIN code.

‹To Program Relocking Timerrelay):

Enter the Programming mode

A.Press「*20Followed by the number of seconds the relay should open→05=5 seconds01 ~99 = secondsbeep→enrolled → Press #to exit from the programming mode, or program other operating.

B.Enter00Sets the relay to latching mode. (Correct code entered opens the relay, and the relay stays open until the correct code is entered again).

‹To Delete a User Code

Enter the Programming mode→ Press the slot position code of your choice to delete (example "06") →Press「*060000beep→deletePress#to exit from the programming mode, or programming other operating.

‹To Change the Master codes:

Enter the Programming mode, Enter「*00Followed by the new 5 digit master code→ beep→enrolledEnter #to exit from the programming mode, or program other operating.

IV. Wiring diagram:

Note:

The varistor or diode must be connected across the lock terminal (electromagnet...) operated by the device. The vartistor controls the overload produced by the strike coil (EMP).

Copyright Gianni Industries, Inc. All Rights Reserved.

 

P-MU-DG10-4C Ver. A Publish:2004.09.07

Page: 2/ 2

Page 2
Image 2
Gianni Industries DG-10 III. Program Instruction, IV. Wiring diagram, ‹ Enter Program Mode, ‹ To Delete a User Code: