Patent:
ZL 2006 2 0122522.X Nr. 20 2006 012 052.1 M308308
GB 06 1 6099.8
06 07229 (France)
Features
MOV provides spike and surge protection.
Automatic relocking time delay
Magnetic bond sensor monitor output.
Bi-color LED indicates lock/unlock status.
Anodized aluminum housing.
Groove template & housing for easy installation.
Dual voltage 12 or 24 VDC (selectable).
Statement
The
Specifications
Voltage Tolerance: ±15%
Current Draw: 500mA@12Vdc;250mA@24Vdc (at 20 degree centigrade)
Operating Temperature from
Humidity: 0~95%
Holding Force: Up to 600 lbs (272 Kg)
Dimensions:
Magnet:(L) 250, (W) 46, (D) 25 mm Armature Plate:(L) 185, (W) 38, (D) 12 mm Mounting Plate:(L) 250, (W) 25, (D) 5 mm
Finishes for magnet and armature plate: Zinc
Epoxy Potting Compound: E87252 (S),
Magnetic bond sensor monitor output (SPDT rated 3A@12V DC), remotely monitors the door lock or unlock status.
Status LED: Lights GREEN when the door is unlocked, lights RED when the door is locked. Automatic relocking time delay: 1~90 seconds.
GIANNI INDUSTRIES, INC.
TEL:
Website: gianni.tw
EM-NH600
Mini Electromagnetic Lock
Operating Features
Bond sensor is used to indicate the door status as in a locked or unlocked condition. Status LED is a
visual feedback for user to give the true status of the lock at any time. Green light indicates the door is insecure (unlocked) and the Red light is indicates the door is secure (locked).
Bond sensor monitor output : SPDT rated: 3A@12VDC
Trigger
|
| SPDTrelay 3A@12VDC |
|
| Relocking Time Delay Switch ensures the |
|
|
| N.O. door is closed properly and it can be | ||
Timer Adjust |
| N.C. | automatically turns to lock mode after the | ||
|
|
|
| COM. |
|
|
| Shorten |
|
| adjusted from 0 to 90 seconds. |
|
| Power |
|
|
|
|
| Input |
|
|
|
|
|
|
|
|
|
Special Mounting Plate design
Cable
Fasten the mounting plate on t h e s i t e t h e n i n s t a l l e l e c t r o m a g n e t l o c k w i t h power lead cable through mounting plate slot hole.
For assembling the mounting plate and the electromagnet lock into the groove, please m a k e t h e m a r k o n t h e mounting plate and the mark on the electromagnet lock itself to be a straight line for alignment. Either aligning from left side or from right side is feasible.
Slide the electromagnetic lock to fit with the mounting plate as the drawing. Once t h e c o r r e c t p o s i t i o n i s encountered, use the Allen Wrench to fasten the fixing screws through the bottom of the electromagnet lock into the mounting plate.
A f t e r t h e e l e c t r o m a g n e t firmly assembled with the m o u n t i n g p l a t e , u s e t h e screws to fasten the lock on the site permanently.
| The products are manufactured under an ISO |
| 9 0 0 1 & Q C 0 8 0 0 0 0 C e r t i f i e d Q u a l i t y |
| Management Program environment back its |
| product quality, performance and commitment |
GP001 | to customer satisfaction. |
Copyright © 2008 Gianni industries, inc. All rights reserved.