Installation Manual

1

2

FDH-100M / FDH-200M Electromagnetic Lock

3

Use 3 mm hexagon tool wrench to operate the screw.

Use 4 mm hexagonal screw to tighten the electromagnet lock.

1.Take out the lock, connect the wires (please see the picture on the right)

2.Once the power source is connected, make a hole for the power wires.

4

5

37 50

Put in the lock, pull out the power lines.

Wiring Diagram

 

N.C.

 

COM.

 

N.O.

Power

-

 

Input

+

 

Screw in the hexagonal screw.

Signal output contact. Withstanding Power: 3A@12Vdc

- Power +

Electric Control Circuit

(N.C. Contact)

12Vdc 24Vdc

voltage setting

GIANNI INDUSTRIES, INC.

No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone, Tu-Cheng City, Taipei, Taiwan 23678

Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876

E-Mail: info@gianni.com.tw

Website: gianni.tw

The products are manufactured under an ISO 9 0 0 1 & Q C 0 8 0 0 0 0 C e r t i f i e d Q u a l i t y Management Program environment back its product quality, performance and commitment to customer satisfaction.

Copyright 2008 Gianni industries, inc. All rights reserved. DM-CA-FDH Ver. C Published on 2008.05.19