INSTALLATION INSTRUCTIONS

Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa- tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

1.The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.

2.The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of

1600 F, it is important to insure a positive head to the pump to prevent cavitation.

3.The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

4.Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- tion. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.

5.Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction desig- nated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be ob- tained from the chart on page 3.

6.Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS

Failure to comply with any of these conditions invalidates the warranty.

1.Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.

Use Giant 20W-50 oil (p/n 01153) or use SAE 80-90W Industrial Gear Lube oil (p/n 01154),

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

2.Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

3.Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

4.Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.

2

Page 2
Image 2
Giant P57-0011 service manual Installation Instructions, Important Operating Conditions

P57-0011, P57 specifications

The Giant P57, specifically the model P57-0011, is an outstanding example of modern engineering and design in the bicycle industry. This versatile bike is tailored to meet the demands of both casual riders and serious cyclists, blending innovative technology with practical performance features.

One of the main attractions of the Giant P57-0011 is its lightweight aluminum frame, which provides both strength and agility. The geometry of the frame is designed to offer a comfortable riding position, making it ideal for long rides as well as short commutes. This design ensures that riders can maintain efficient pedaling without sacrificing comfort, which is a critical factor for many cyclists.

The P57-0011 is equipped with an advanced suspension system that enhances its versatility across various terrains. With a front suspension fork that can absorb shocks from rough paths and potholes, riders will experience a smoother ride whether they are tackling city streets or venturing into more rugged landscapes. This feature also contributes to the bike’s overall stability and control.

In terms of performance, the Giant P57-0011 boasts an impressive gear system. The bike is fitted with a high-quality drivetrain that allows for smooth and precise shifting, ensuring that cyclists can easily navigate different inclines and speeds. Riders will appreciate the seamless transitions between gears, which enhance overall efficiency.

The braking system on the P57-0011 also deserves mention. It utilizes hydraulic disc brakes that provide reliable stopping power in all weather conditions. This feature is particularly vital for those who ride in varying climates or during inclement weather, offering peace of mind and added safety on the road.

Additional features of the Giant P57 include ergonomic grips and a padded saddle, enhancing comfort during long rides. The bike is also designed to accommodate various accessories, such as racks and fenders, making it adaptable for commuting, touring, or recreational riding.

In summary, the Giant P57-0011 is a well-rounded bike that integrates modern technologies with practical designs. Its lightweight frame, advanced suspension, reliable drivetrain, and superior braking system set it apart in the competitive cycling market. Whether for daily commutes or weekend adventures, the P57-0011 caters to a wide range of cycling needs, reaffirming Giant's commitment to quality and innovation in the biking industry.