The PERS-2400 Console is a supervised wireless emergency reporting product designed for medical alert applications. The table-top or wall-mount Console provides “pushbutton” emergency assistance to anyone who desires additional security and peace of mind.

The Console has three emergency functions: emergency, fire, and activity. The emergency zone can be triggered by the large EMERGENCY button on the face of the Console or with various models of wireless transmitters.The fire zone can be triggered by wireless smoke alarms.The optional activity timer can be set for 8, 12 or 24 hour operation. If the time expires before an activity transmitter is activated, or the HOME button is pressed on the Console, the inactivity will trigger the emergency zone. For the visually impaired, each button on the Console is molded with braille characters to identify the button’s function.

The Console is programmed using Linear’s RA-2400 remote access software. For details on using the RA-2400 software, refer to the software’s built-in help file.

The Console can receive signals from Linear’s wireless battery-powered transmitterssending DX orDXS format signals. Up to 16 individual transmitters can be used with the Console. Activating a transmitter causes the Console’s built-in digital communicator to send the appropriate alarm report to the central monitoring station via the standard telephone network. In addition to the central station report, audible and visual indications occur and the alarm relay energizes during an emergency activation.

If the optional Model VB-4 voice board is installed, the Console will “talk” to the user. The digitally synthesized, actual human voice, will sound “emergency”, “fire”, “timer done soon”, and other system operation, setup, and supervisory prompts from a 38 word vocabulary. In addition, the voice board supports 2-way automatic, 2-way manual, and 1-way listen-only audio emergency communications with central station monitoring personnel using the Console’s built-in high-sensivity microphone and speaker. Supervised transmitters regularly send status reports to the Console and low battery reports when their batteries are low.When the Console receives a low battery report, the TROUBLE indicator flashes.If the Console fails to receive a status report from a transmitter for a period of 24 hours, the TROUBLE indicator will light.All supervisory conditions can sound a local annunciation and be reported to the central station. The Console’s digital communicator can route calls to three telephone numbers:primary, secondary, and supervisory. General reporting codes and individual sensor reporting codes are programmable for the 4x2 format. Alternately, Ademco Contact ID may be selected for the communicator reporting format.

Powered by a low voltage plug-in transformer, the Console has provisions for a recharagable backup battery for operation during AC power outages. A backup battery disconnect switch allows for out-of-service storage of the Console without discharge of the battery. The battery is recharged and supervised by the Console. If the backup battery becomes low the POWER light will flash and the condition can be reported to the central station.

A variety of Linear’s transmitters can be used with the Console. Supervised and non-supervised transmitters in DX or DXS format can be used. The Consoles three zones function as follows:

EMERGENCY

Portable, supervised and non-supervised, pendant, belt-clip, or wristband type transmitters (Models DXT-41, DXT-42, DXT-61A, DXS-21, DXS-23, DXS-62, DXS-63) and stationary, supervised Model DXS-31 transmitters are used for medical alert applications. When this type of transmitter is triggered, the Console sounds a two-tone siren and an emergency report will be sent to the central station. The emergency zone can also be triggered by pressing the EMERGENCY button.

FIRE

Supervised Model DXS-72 wireless photoelectric smoke alarms can trigger the fire zone.When a smoke alarm is activated, the Console sounds a repeated series of three beeps and a fire report will be sent to the central station.

ACTIVITY

Supervised, switch or motion triggered transmitters (Models DXS-31/DXS-32 and DXS-54) can be used for ensuring human activity. The motion detector will monitor human presence in a room. The contact activated transmitter can be wired to a pushbutton or switch for manual activity monitoring. As long as a signal is received at least once every 8, 12, or 24 hours (programmable) an alarm will not be triggered. 15 minutes before the programmed time expires, the HOME indicator will start blinking and a low pitched beep will sound every ten seconds.Theactivitytimercanberesetwithasignalfromoneofthesetransmitters orbypressingtheHOMEbuttonontheConsole.Failuretoreceiveasignalwithintheprogrammedtimeperiod will cause the Console to sound the two-tone emergency siren and report an inactivity alarm to the central station. The activity timer can be turned on or off at the Console or through programming.

WIRELESS INSTALLATION TIPSWALLBOARD ANDWOOD STUDS

 

CONSTRUCTION

 

 

90% - 100%

MATERIALS WILLCENTRALLY LOCATE CONSOLE

 

EFFECT RADIO RANGE

 

 

OF FULL POWER

 

 

RIGHT

 

 

 

LIGHT CONCRETE

CONCRETE WITH STEEL

CONSOLE LOCATION WILL

 

EFFECT RADIO RANGE

 

OR BRICK

REINFORCEMENT OR

 

 

METAL LATH AND PLASTER

 

 

65% - 95%

10% - 70%

 

 

OF FULL POWER

 

 

OF FULL POWER

TRANSMITTERS AT THE OTHER END OF

 

 

WRONG!

 

 

 

 

HOUSE MIGHT BE TOO FAR AWAY

 

 

 

FRONT PANEL FEATURES
REMOVING BOTTOM COVER

 

 

PERS-2400

PERSONAL

EMERGENCY

REPORTING

SYSTEM

Installation Instructions
(760) 438-7000 • FAX (760) 438-7043USA & Canada (800) 421-1587 & (800) 392-0123Toll Free FAX (800) 468-1340www.linearcorp.com

 

 

SYSTEM OVERVIEW

EMERGENCY

 

FIRE

 

 

R

 

DXT-41DXT-42

A

 

 

 

D

DXS-72

 

 

I

 

 

 

 

 

O

 

DXT-61A DXS-21DXS-23

S

ACTIVITY

I

 

 

 

 

 

 

G

 

 

 

N

 

 

 

A

 

DXS-62DXS-63

L

 

S

DXS-31/32
DXS-31

 

 

 

 

 

DXS-54

TO CENTRAL STATION

VIA TELEPHONE
CONSOLE
CONSOLE BOTTOM FEATURES
TROUBLE INDICATOREMERGENCY BUTTON
• NORMALLY OFF• PRESS AND HOLD TO TRIGGER
• LIGHTS WHEN ANY TRANSMITTERS ARE MISSING (SUPERVISORY)THE EMEREGNCY ZONE
• BLINKS SLOWLY WHEN ANY TRANSMITTERS HAVE A LOW BATTERY

 

POWER INDICATORCLEAR BUTTON
• LIGHTS WHEN AC IS PRESENT
• STOPS ALARM
• BLINKS SLOWLY WHEN BATTERY IS CHARGING
• ADDS CANCEL TO AN ALARM
• BLINKS QUICKLY WHEN AC IS ABSENT (CONSOLE ON BATTERY POWER)
REPORT IN PROGRESS
• OFF IN TEST AND SETUP MODES
• PRESS IMMEDIATELY AFTER

 

 

EMERGENCY TO PREVENT REPORT

 

• CLEARS INDICATORS

 

• STOPS TROUBLE BEEPER

 

• PRESS FOR 5 SECONDS TO ADD

 

A TRANSMITTER

 

HOME BUTTON

 

• PRESS TO RESET ACTIVITY TIMER

 

• PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER OFF
HOME INDICATOR• IF ACTIVITY TIMER IS OFF, PRESS FOR
5 SECONDS TO TURN ACTIVITY TIMER ON
LIGHTS WHEN ACTIVITY TIMER IS ONBLINKS SLOWLY WHEN LESS THAN 15 MINUTES IS LEFT ON THE ACTIVITY TIMERBLINKS QUICKLY WHEN THE ACTIVITY TIMER HAS EXPIRED
SENDING INDICATOR

HOME BUTTON COVER

• NORMALLY OFF

• ADHESIVE BACKED PLATE TO

HIDE THE HOME BUTTON IF THE

• FLASHES WHEN CONSOLE IS PLACING A CALL

ACTIVITY TIMER IS NOT USED

 

OPTIONAL MODEL VB-4 VOICE BOARD INSTALLATION
TO ACCESS THE INSIDE OF THE CONSOLEPRESS THE TWO LOCKING TABS IN ANDREMOVE THE CONSOLE'S BOTTOM COVER

REMOVE

COVERPRESSTABS

IN

BACKUP BATTERY

1

2

CONNECT BLACKMICROPHONEWIRE TO CENTERTERMINAL

PRESS-FIT MICROPHONE INTO ROUND MOUNTING HOLE

2 CONNECT RED LEAD TO POSITIVE AND BLACK LEAD TO NEGATIVE BATTERY TERMINAL

16 VAC 1.25 AMPPLUG-INTRANSFORMER

EXTERNAL SPEAKER AND RELAY OUTPUT TERMINALS

VOICE DIALER JACKLOCAL PHONE SET JACKTELEPHONE LINE JACK

12-VOLT 1.2 AMP/HOUR

BACKUP BATTERYOPTIONALVB-4 VOICE BOARD
CONNECT REDMICROPHONE WIRE TOTHIS TERMINAL

3

4

SEAT

MICROPHONE

5

CAREFULLY ALIGN PINS TO CONNECTORS ON BOTH ENDS OF BOARD

BE SURE THAT THE WHITE ARROWS ON AUDIO BOARD POINT TOWARDS THE BATTERY AREA

ON

OFF

BATTERY TYPE: 12-VOLT, 1.2 AMP/HOUR

1TURN BATTERY SWITCH OFF

3FIT BATTERY INTO CONSOLE

SLIDE DOWN
BATTERY SWITCH3 AMP 2AG

BATTERY FUSETEST BUTTON (HIDDEN)

NOTE: POWER MUST BE OFF AND BATTERY SHOULD BE REMOVED OR DISCONNECTED BEFORE INSTALLING THE AUDIO BOARD

PRESS BOARD COMPLETELY INTO CONNECTORS

NOTE: AFTER THE AUDIO BOARD IS INSTALLED AND ENABLED,

THE CONSOLE WILL SPEAK INSTEAD OF BEEP DURING PROGRAMMING

THEN BACK
OPTIONAL MODEL RSM-1 REMOTE SPEAKER/MIC CONNECTIONS
OPTIONAL RELAY OUTPUT CONNECTIONS
INSTALL TRANSFORMER
VB-4VOICEBOARD

 

REMOVE

 

JUMPER

VB-4 TERMINAL BLOCK

WIRE

 

EXTERNAL MICROPHONE (+)

5

 

MICROPHONE COMMON (-)PERS-2400 CONSOLE
4 TERMINAL BLOCK
CONSOLE MICROPHONE (+)

3

 

USE TWISTED2 - EXTERNAL SPEAKER
PAIR WIRE FOR1 - EXTERNAL SPEAKER
MICROPHONE

 

NOTE: REMOVE

 

JUMPER WHEN

 

USING AN

 

EXTERNAL SPKR

 

SPKR

 

NOISEMAKER OR VISUAL INDICATOR

EXTERNALPOWER SUPPLY

FORM C DRY CONTACT RELAY 24 VOLTS AT 1 AMP MAXIMUM

5 - NORMLLY OPEN4 - NORMALLY CLOSED3 - RELAY COMMON

2

1

PERS-2400 CONSOLE

CONNECT WIRES
TO TERMINALS

1

TURN BATTERY

ON

SWITCH ON

 

OFF

3

SECURE

2

TRANSFORMER

 

WITH SCREW
SPKRNOTE: NOT

 

MIC (-)TESTED BY UL

 

 

 

MIC (+)

 

 

RSM-1 TERMINAL BLOCK

 

RSM-1
LINEAR MODEL RSM-1TERMINALS

 

ROUTE CABLE UNDER
STRAIN-RELIEF CLAMP

PLUG TRANSFORMER INTO AN UN-SWITCHED 117 VAC OUTLET