11.Re-fit and re-set the riving knife and the saw blade guard.

12.Replace the table insert.

13.Before using the saw again, check that all safety devices are in good working order.

IMPORTANT. After replacing the saw blade, make sure the saw blade runs freely by turning the blade by hand.

14.Plug the machine into a mains socket and run the saw at no load before using it to cut any materials.

Maintenance

WARNING. Always ensure that the tool is switched off and the plug is removed from the power point before making and adjustments or maintenance procedures.

Power cord maintenance

If the supply cord needs replacing, the task must be carried out by the manufacturer, the manufacturer’s agent, or an authorised service centre in order to avoid a safety hazard.

Cleaning

1.Keep the tool’s air vents unclogged and clean at all times.

2.Remove dust and dirt regularly. Cleaning is best done with a soft brush or a rag.

3.Re-lubricate all moving parts at regular intervals.

4.Never use caustic agents to clean plastic parts.

CAUTION. Do not use cleaning agents to clean the plastic parts of the saw. A mild detergent on a damp cloth is recommended.

General inspection

Regularly check that all the fixing screws are tight. They may vibrate loose over time.