LINE VOLTAGE ADJUSTMENT

3

4

LINE VOLTAGE ADJUSTMENT

An AC line voltage selection is possible inside the chassis. Please ask your dealer for assistance if the line voltage provided is not appropriate.

ATTENTION

On the 220V position, the GOLDMUND SR150 amplifier will function properly for AC voltages between 200V and 245V.

On the 110V position, the AC line must deliver between 95V and 125V. If your AC line is usually out of these tolerances, please consult your GOLDMUND dealer.

Please check the value of the mains line fuse. This fuse is located in the power cord receptacle. The lid can be removed with a small screwdriver when the cord is removed.

Use a 5A slow-blow fuse for 220V and a 8A slow-blow fuse for 110V.

CONNECTIONS

Check if volume control is down to zero on the preamplifier.

If you are using analog inputs, connect the interconnects between the preamp/processor and each of the power amps inputs.

If you are using a Goldmund Universal Preamplifier, connect a lineal digital cable between one of the preamp outputs and the amplifier digital input. Then change the amp switch back to digital input.

Connect the speaker cables to the red and black terminals accessible at the back of the amplifiers.

You may notice that the ground of the input and the black speaker terminal are of the same polarity. The amplifier is non-inverting in phase.

Then, connect the power cords to the back of the amplifier and plug it in the nearest wall plug. Use a 3 lugs grounded plug, for safety reasons. To get the best sound of the amplifier, avoid any multiple plug or extension cord.

User manual - SR150 2-CHANNEL UNIVERSAL POWER AMPLIFIER P 5